YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
839
■
43: FWD/REV (2-Wire Sequence 2)
Setting Value
Function
Description
43
FWD/REV (2-Wire
Sequence 2)
Sets the direction of motor rotation for 2-wire sequence 2. Set this function and
H1-xx = 42 [Run Command (2-Wire Sequence 2)]
together.
ON : Reverse
OFF : Forward
Note:
•
You must input the Run command to rotate the motor.
•
This function will not operate at the same time as
H1-xx = 40, 41 [Forward/Reverse Run Command (2-Wire Seq)]
.
■
44: Add Offset Frequency 1 (d7-01)
Setting Value
Function
Description
44
Offset Frequency 1
Sets the function to add the offset frequency set in
d7-01 [Offset Frequency 1]
to the frequency reference when the terminal
activates.
Note:
Refer to
“
d7: Offset Frequency
”
for more information.
■
45: Add Offset Frequency 2 (d7-02)
Setting Value
Function
Description
45
Offset Frequency 2
Sets the function to add the offset frequency set in
d7-02 [Offset Frequency 2]
to the frequency reference when the terminal
activates.
Note:
Refer to
“
d7: Offset Frequency
”
for more information.
■
46: Add Offset Frequency 3 (d7-03)
Setting Value
Function
Description
46
Offset Frequency 3
Sets the function to add the offset frequency set in
d7-03 [Offset Frequency 3]
to the frequency reference when the terminal
activates.
Note:
Refer to
“
d7: Offset Frequency
”
for more information.
■
47: Node Setup (CANopen)
Setting Value
Function
Description
47
Node Setup (CANopen)
Sets the function in CANopen communications to start the Node Setup function to set the drive node address from the host
controller.
■
60: DC Injection Braking Command
Setting Value
Function
Description
60
DC Injection Braking
Command
Sets the command to use DC Injection Braking to stop the motor.
If you input the Run command or JOG command, it will cancel DC Injection Braking.
shows the time chart of the DC Injection Braking function.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...