782
YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
The drive ramps the motor to stop in the deceleration time. Fault relay output terminal MA-MC turns ON, and MB-
MC turns OFF.
1 : Coast to Stop
The output turns off and the motor coasts to stop. Fault relay output terminal MA-MC turns ON, and MB-MC turns
OFF.
2 : Fast Stop (Use C1-09)
The drive stops the motor in the deceleration time set in
C1-09 [Fast Stop Time]
. Fault relay output terminal MA-MC
turns ON, and MB-MC turns OFF.
3 : Alarm Only
The keypad shows
oS
and the drive continues operation. Only use this setting in special conditions to prevent damage
to the motor and machinery. The output terminal set for
Alarm [H2-01 to H2-03 = 10]
activates.
Note:
When
A1-02 = 6 [Control Method Selection = AOLV/PM]
, the drive will automatically set
F1-03 = 1 [Coast to Stop]
. You cannot change
this value.
■
F1-04: Speed Deviation Detection Select
No.
(Hex.)
Name
Description
Default
(Range)
F1-04
(0383)
Speed Deviation Detection
Select
Sets the method to stop the motor or let the motor continue operating when the drive detects
dEv
[Speed Deviation]
.
3
(0 - 3)
When the difference between the frequency reference and the motor speed is more than the value set in
F1-10 [Speed
Deviation Detection Level]
for longer than the time set in
F1-11 [Speed Deviation Detect DelayTime]
, the drive will
detect
dEv
.
0 : Ramp to Stop
The drive ramps the motor to stop in the deceleration time. Fault relay output terminal MA-MC turns ON, and MB-
MC turns OFF.
1 : Coast to Stop
The output turns off and the motor coasts to stop. Fault relay output terminal MA-MC turns ON, and MB-MC turns
OFF.
2 : Fast Stop (Use C1-09)
The drive stops the motor in the deceleration time set in
C1-09 [Fast Stop Time]
. Fault relay output terminal MA-MC
turns ON, and MB-MC turns OFF.
3 : Alarm Only
The keypad shows
dEv
and the drive continues operation. Only use this setting in special conditions to prevent
damage to the motor and machinery. The output terminal set for
Alarm [H2-01 to H2-03 = 10]
activates.
■
F1-05: Encoder 1 Rotation Selection
No.
(Hex.)
Name
Description
Default
(Range)
F1-05
(0384)
Encoder 1 Rotation Selection
Sets the output sequence for the A and B pulses from the encoder, assuming that the motor is
operating in the forward direction.
Determined by A1-02
(0, 1)
Refer to the option card installation manual for more information about how to set the encoder pulse output sequence
and make sure that it is correct.
0 : Pulse A leads in FWD Direction
1 : Pulse B leads in FWD Direction
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...