680
YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
■
b3-09: Speed Estimation ACR I Time
No.
(Hex.)
Name
Description
Default
(Range)
b3-09
(0199)
Speed Estimation ACR I
Time
Sets the integral time for the automatic current regulator during Speed Estimation Speed Search. Also
adjusts speed search responsiveness. Usually it is not necessary to change this setting.
Determined by A1-02 when
A1-02 ≠ 5
20.0 when A1-02 = 5
(0.0 - 1000.0 ms)
■
b3-10: Speed Estimation Detection Gain
No.
(Hex.)
Name
Description
Default
(Range)
b3-10
(019A)
Expert
Speed Estimation Detection
Gain
Sets the gain to correct estimated frequencies from Speed Estimation Speed Search.
1.05
(1.00 - 1.20)
If the drive detects
ov [DC Bus Overvoltage]
when you restart the motor, increase the setting value.
■
b3-14: Bi-directional Speed Search
No.
(Hex.)
Name
Description
Default
(Range)
b3-14
(019E)
Bi-directional Speed Search
Sets the direction of Speed Search to the direction of the frequency reference or in the motor rotation
direction as detected by the drive.
Determined by A1-02 and
b3-24
(0, 1)
Note:
•
Refer to
Parameters that Change from the Default Settings with A1-02 [Control Method Selection] on page 590
for information about the
initial value of
b3-14 [Bi-directional Speed Search]
that applies when you set these parameters:
–
A1-02 = 0, 2, 8 [Control Method Selection = V/f, OLV, EZOLV]
–
E9-01 = 0 [Motor Type Selection = Induction (IM)]
–
b3-24 = 1 [Speed Search Method Selection = Speed Estimation Speed Search]
•
The initial value of
b3-14
is 0 when you set these parameters:
–
A1-02 = 0, 2, 8
–
E9-01 = 0
–
b3-24 = 2 [Current Detection 2]
•
Refer to
Parameters that Change from the Default Settings with A1-02 [Control Method Selection] on page 590
for information about the
initial value of
b3-14
that applies when you set these parameters:
–
A1-02 = 1, 4, 8[CL-V/f, AOLV, EZOLV]
–
E9-01 = 1, 2 [Permanent Magnet (PM), Synchronous Reluctance (SynRM)]
•
When you change
A1-02
,
b3-24
, and
E9-01
, also set
b3-14
.
0 : Disabled
The drive uses the frequency reference to detect the direction of motor rotation.
1 : Enabled
The drive detects the direction of motor rotation during Speed Search.
■
b3-17: Speed Est Retry Current Level
No.
(Hex.)
Name
Description
Default
(Range)
b3-17
(01F0)
Expert
Speed Est Retry Current
Level
Sets the current level for the search retry function in Speed Estimation Speed Search as a percentage
where drive rated current is a setting value of 100%.
150%
(0 - 200%)
When a large quantity of current flows during Speed Estimation Speed Search, the drive temporarily stops operation
to prevent overvoltage and overcurrent. When the current is at the level set in
b3-17
, the drive tries speed search
again.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...