The Drive Frequency Reference Is Different than the Controller Frequency
Reference Command
Causes
Possible Solutions
The analog input gain and bias for the frequency reference input are set
incorrectly.
Examine the gain and bias settings for the analog inputs that set the frequency reference.
•
Terminal A1:
H3-03 [Terminal A1 Gain Setting]
,
H3-04 [Terminal A1 Bias Setting]
•
Terminal A2:
H3-11 [Terminal A2 Gain Setting]
,
H3-12 [Terminal A2 Bias Setting]
•
Terminal A3:
H3-07 [Terminal A3 Gain Setting]
,
H3-08 [Terminal A3 Bias Setting]
The drive is receiving frequency bias signals from analog input terminals A1 to
A3 and the sum of all signals makes the frequency reference.
•
Examine parameters
H3-02, H3-10, H3-06 [MFAI Function Select]
. If two or more of these
parameters are set to
0
, change the settings.
•
Use
U1-13 to U1-15 [Terminal A1, A2, A3 Input Voltage]
to make sure that the analog input
values set to terminals A1, A2, and A3 are applicable.
The motor rotates faster than the frequency reference at low speed.
Reduce the value set in
n4-70 [Speed Command Comp @ Low Freq]
.
PID control is enabled.
If PID control is not necessary, set
b5-01 = 0 [PID Mode Setting = Disabled]
.
Note:
When PID control is enabled, the drive adjusts the output frequency as specified by the target
value. The drive will only accelerate to the maximum output frequency set in
E1-04 [Maximum
Output Frequency]
while PID control is active.
◆
The Motor Speed Is Not Stable When Using a PM Motor
Causes
Possible Solutions
E5-01 [PM Motor Code Selection]
is set incorrectly.
Refer to
“
Motor Performance Fine-Tuning
”
in the technical manual.
The drive is operating the motor at more than the specified speed control range.
Examine the speed control range and adjust the speed.
The motor is hunting.
Adjust these parameters to have the largest effect:
•
n8-55 [Motor to Load Inertia Ratio]
•
n8-45 [Speed Feedback Detection Gain]
•
C4-02 [Torque Compensation Delay Time]
Hunting occurs at start.
Increase the value set in
C2-01 [S-Curve Time @ Start of Accel]
.
Too much current is flowing through the drive.
Set
E5-01 [PM Motor Code Selection]
correctly as specified by the motor. For special-purpose
motors, enter the correct value to
E5-xx
as specified by the motor test report.
Operation is not stable when
n8-57 = 1 [HFI Overlap Selection = Enabled]
.
•
Do High Frequency Injection Auto-Tuning.
•
Decrease the value set in
n8-41 [HFI P Gain]
in increments of 0.5.
Note:
Set
n8-41 > 0.0
for IPM motors.
◆
There Is Too Much Motor Oscillation and the Rotation Is Irregular
Causes
Possible Solutions
Unsatisfactory balance of motor phases.
•
Make sure that the drive input power voltage supplies stable power.
•
Set
L8-05 = 0 [Input Phase Loss Protect Select = Disabled]
.
The motor is hunting.
•
Set
n1-01 = 1 [Hunting Prevention Selection = Enabled]
.
•
Increase the value of
n2-01 [SpdFeedbackDetectCtr (AFR) Gain]
or
n2-02 [SpdFeedbackDetCtr
(AFR)TimeConst1]
.
◆
Deceleration Takes Longer Than Expected When Dynamic Braking Is Enabled
Causes
Possible Solutions
The stall prevention during deceleration setting is incorrect.
•
Examine the setting for
L3-04 [Decel Stall Prevention Selection]
.
•
When the drive has a dynamic braking option installed, set
L3-04 = 0 [Disabled]
.
•
If the drive detects
ov [Overvoltage]
, set
L3-04 = 3 [General Purpose w/ DB resistor]
.
The deceleration time setting is too long.
Set
C1-02, C1-04, C1-06, or C1-08 [Deceleration Times]
to applicable values.
The motor torque is not sufficient.
Use a larger motor.
Note:
If these items are correct, the demand on the motor is more than the motor capacity:
•
Parameter settings are correct.
•
The drive does not detect
ov [Overvoltage]
.
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...