4.3 Installation Position and Clearances
310
YASKAWA
TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
A - 50 mm (2 in) minimum
B - 30 mm (1.2 in) minimum on each side
C - 2 mm (0.08 in) minimum between each drive
D - 120 mm (4.7 in) minimum above and below
Figure 4.3 Installation Clearances for More than One Drive (Side-by-Side)
Note:
•
Align the tops of drives that have different dimensions to help when you replace cooling fans.
•
Remove the top protective covers of all drives when you mount IP20/UL Type 1 drives side-by-side.
Figure 4.4 IP20/UL Type 1 Drives Installed Side-by-Side