![YASKAWA FSDrive-MV1S Скачать руководство пользователя страница 207](http://html1.mh-extra.com/html/yaskawa/fsdrive-mv1s/fsdrive-mv1s_instructions-manual_3478741207.webp)
8
-8
Periodic Maintenance of Parts
In order to keep the FSDrive-MV1S series Inverter operating normally over a long period of time, we recom-
mend replacing parts in accordance with their service life.
The Inverter is configured with many parts, and these parts must be operating properly in order to make full
use of the Inverter functions. Among the electronic components, there are some that require maintenance
depending on their usage conditions.
Periodic inspection standards vary, depending on the Inverter installation environment and usage conditions.
Inverter maintenance periods are noted below for your reference.
Refer to Page 8-12 for the replacement procedure for the cooling fan.
For replacement of other parts, contact your Yaskawa representative. These replacements require trained pro-
fessionals.
* The standard replacement period is based on the following usage conditions.
•Ambient temperature: Yearly average of 30
°
C.
•Load factor: 80% max.
•Operating rate: 12 hours max./day
Table 8.3 Part Replacement Guidelines
Part Name
Standard Replacement Period*
Replacement Method and Remarks
Cooling fan
1 to 2 years
(15,000 service hours)
Replace the bearings.
(Bearings on motor and fan)
Power cell smoothing
capacitor
5 years
Replace with a new capacitor.
(Determine replacement need after inspection.)
Fuses
10 years
Replace with new fuses.
Aluminum capacitor on
the printed circuit board
5 years
Replace with a new board.
(Determine replacement need after inspection.)
Lithium battery
5 years
Replace with a new battery (Connect a battery to the
CPU board with connector.)
Type: 000025, Specifications: 3 V/2000 mAh
Product name: CR6L-CN014S manufactured by
FDK Corporation
Breaker and power fuses
−
Determine replacement need after inspection.