Transporting
The method of transport differs depending on the model of drive.
Transport the drive by using the appropriate method indicated in the table below.
Table 2.3 Models and Transportation Methods
Voltage
Class
(kV)
Nominal
Capacity
(kVA)
Motor Power
(HP)
Transportation Method
2
220 to 560
200 to 600
Use the support hooks on the top of the drive to lift the drive.
For details on the transportation procedure, refer to
670 to 1620
700 to 1750
Use the support hooks to lift the transformer panel.
For details on the transportation procedure, refer to
Use the support hooks on the top of the drive to lift the Power Cell and control panels.
For details on the transportation procedure, refer to
1830 to 2500
2000 to 2750
Use the support hooks to lift the transformer panel.
For details on the transportation procedure, refer to
Use the support hooks on the top of the drive to lift the Power Cell and control panels.
For details on the transportation procedure, refer to
3
200 to 800
132 to 630
Use the support hooks on the top of the drive to lift the drive.
For details on the transportation procedure, refer to
1150 to 2300
900 to 1800
Use the support hooks to lift the transformer panel.
For details on the transportation procedure, refer to
Use the support hooks on the top of the drive to lift the Power Cell and control panels.
For details on the transportation procedure, refer to
3000 to 3700
2500 to 3000
Use the support hooks to lift the transformer panel.
For details on the transportation procedure, refer to
Use the support hooks on the top of the drive to lift the Power Cell and control panels.
For details on the transportation procedure, refer to
4
375 to 900
400 to 1000
<1> The following models are under development.
2-kV class: 700 to 1750 HP, 2000 to 2750 HP
4-kV class: 1750 to 3000 HP, 3500 to 5000 HP
11-kV class: 5000 to 12000 kVA
Use the support hooks on the top of the drive to lift the drive.
For details on the transportation procedure, refer to
1120 to 2700
1250 to 3000
Use the support hooks to lift the transformer panel.
For details on the transportation procedure, refer to
Use the support hooks on the top of the drive to lift the Power Cell and control panels.
For details on the transportation procedure, refer to
3170 to 4500
3500 to 5000
Use the support hooks to lift the transformer panel.
For details on the transportation procedure, refer to
Use the support hooks on the top of the drive to lift the Power Cell and control panels.
For details on the transportation procedure, refer to
6
400 to 2300
250 to 1800
Use the support hooks to lift the transformer panel.
For details on the transportation procedure, refer to
Use the support hooks on the top of the drive to lift the Power Cell and control panels.
For details on the transportation procedure, refer to
3000 to 7500
2500 to 6000
Use the support hooks to lift the transformer panel.
For details on the transportation procedure, refer to
Use the support hooks on the top of the drive to lift the Power Cell and control panels.
For details on the transportation procedure, refer to
11
660 to 3800
530 to 3050
Use the support hooks to lift the transformer panel.
For details on the transportation procedure, refer to
Use the support hooks on the top of the drive to lift the Power Cell and control panels.
For details on the transportation procedure, refer to
5000 to 12000
3960 to 9910
Use the support hooks to lift the transformer panel.
For details on the transportation procedure, refer to
Use the support hooks on the top of the drive to lift the Power Cell and control panels.
For details on the transportation procedure, refer to