Error Name
ndAT
Model, Voltage Class, Capacity Mismatch
Cause
Possible Solutions
The drive from which the parameters were
copied and the drive to which the parameters
will be written have different electrical
specifications, capacities, are set to different
control modes, or are different models.
Make sure model numbers and specifications are the same for both drives.
The drive or USB Copy Unit being used to write
the parameters is blank and does not have any
parameters saved on it.
Make sure all connections are correct, and copy the parameter settings onto the USB Copy Unit
or the digital operator.
Digital Operator Display
Error Name
rdEr
Error Reading Data
Cause
Possible Solutions
Failed while attempting to read parameter
settings from the drive.
⇒
Press and hold the READ key on the USB Copy Unit for at least one second to have the unit
read parameters from the drive.
Digital Operator Display
Error Name
rEAd
Reading Parameter Settings (flashing)
Cause
Possible Solutions
Displayed while the parameter settings are being
read onto the USB Copy Unit.
This is not an error.
Digital Operator Display
Error Name
vAEr
Voltage Class, Capacity Mismatch
Cause
Possible Solutions
The drive from which the parameters were
copied and the drive on which the Verify mode is
being performed have different electrical
specifications or are different capacities.
Make sure electrical specifications and capacities are the same for both drives.
Digital Operator Display
Error Name
vFyE
Parameter settings in the drive and those saved to the copy function are not the same
Cause
Possible Solutions
Indicates that parameter settings that have been
Read and loaded onto the Copy Unit or digital
operator are different.
To synchronize parameters, either copy the parameter settings on the USB Copy Unit or the
digital operator and save them in the drive, or copy the parameter settings on the drive and save
them in the USB Copy Unit or the digital operator.
Digital Operator Display
Error Name
vrFy
Comparing Parameter Settings (flashing)
Cause
Possible Solutions
The Verify mode has confirmed that parameter
settings on the drive and parameters read to the
copy device are identical.
This is not an error.
Содержание FSDrive-MV1000 Series
Страница 8: ...8 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...
Страница 38: ...1 4 Component Names and Configurations 38 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...
Страница 106: ...3 9 Wiring Check 106 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...
Страница 136: ...4 9 Checking and Saving Parameter Default Values 136 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...
Страница 210: ...6 7 Spare Parts 210 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...
Страница 222: ...B 1 European Standards 222 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...