3.2 Operating Procedures for Utility Functions
3.2.37 Program Table Initialization (FnB06)
3-120
*
If the
key is pressed in an operation prohibited state, “Error.” is displayed for
approximately 2 seconds and then the display returns to the JOG speed table editing
screen. In this case, make the setting again by referring to
3.2.37
Program Table Initialization (FnB06)
This function initializes the program tables and restores the settings on
shipment from the factory.
Preparation
Always check the following before you initialize a program table.
•
The parameters must not be write-prohibited (Fn010 must be set to
0000).
•
The program must not be running or on hold.
•
A program table save operation must not be in progress for any
means other than the digital operator.
•
Execution of the RES command must not be in progress.
3
Move the cursor with the
keys to select “STORE”.
Note: Selecting “CANCEL” and pressing
the
key will return the display
to the JOG speed table editing
screen.
4
Press the
key to start saving
the JOG speed table to flash mem-
ory.
*
Do not turn off the control power
supply until saving has been com-
pleted normally.
5
When saving to flash memory has
been completed normally, the dis-
play returns to the JOG speed table
editing screen.
6
Press the
key to return to the
Utility Function Mode main menu.
Continued from previous page.
Step
Operation
Result