3.2 Operating Procedures for Utility Functions
3.2.15 Write Prohibition Setting (Fn010)
3-38
3.2.15
Write Prohibition Setting (Fn010)
You can use this utility function to restrict executing the utility functions
to prevent careless changes to the parameter settings.
When you prohibit writing, writing parameters and executing utility func-
tions are restricted as described below.
•
Parameters: The settings of parameters cannot be changed. If you
attempt to change the setting of a parameter,
NO-OP
will flash on the display and the display will return to the
Main Menu.
•
Utility functions:Some of the utility functions cannot be executed. If
you attempt to execute one of these utility functions,
NO-OP
will flash on the display and the display will
return to the Main Menu. The following table shows
which utility functions cannot be executed.
Fn No.
Function
When Writing Is Pro-
hibited
Fn000
Display Alarm History
Can be executed.
Fn002
Jog
Cannot be executed.
Fn003
Origin Search
Cannot be executed.
Fn004
Jog Program
Cannot be executed.
Fn005
Initialize Parameters
Cannot be executed.
Fn006
Clear Alarm History
Cannot be executed.
Fn008
Reset Absolute Encoder
Cannot be executed.
Fn009
Autotune Analog (Speed/Torque) Reference
Offset
Cannot be executed.
Fn00A
Manually Adjust Speed Reference Offset
Cannot be executed.
Fn00B
Manually Adjust Torque Reference Offset
Cannot be executed.
Fn00C
Adjust Analog Monitor Output Offset
Cannot be executed.
Fn00D
Adjust Analog Monitor Output Gain
Cannot be executed.
Fn00E
Autotune Motor Current Detection Signal Off-
set
Cannot be executed.
Fn00F
Manually Adjust Motor Current Detection Sig-
nal Offset
Cannot be executed.
Fn010
Write Prohibition Setting
Cannot be executed.
Fn011
Display Servomotor Model
Can be executed.
Fn012
Display Software Version
Can be executed.
Fn013
Multiturn Limit Setting after Multiturn Limit
Disagreement Alarm
Cannot be executed.
Fn014
Reset Option Module Configuration Error
Cannot be executed.
Continued on next page.