11.4 Applications Examples for Safety Functions
11.4.3 Procedure
11-10
11.4.3
Procedure
1
2
3
4
5
6
7
Request is received to open the guard.
The guard is opened.
The worker leaves the guarded area after completing work.
The guard is closed.
The servo is turned ON by the host controller.
The /HWBB1 and /HWBB2 signals turn OFF and the HWBB
operates. (Working inside the guard is enabled.)
If the Servomotor is operating, a stop command is received from the
host controller, the Servomotor stops, and the servo is turned OFF.