4.8 Connecting the Other Connectors
4.8.1 Serial Communications Connector (CN3)
4-48
4.8
Connecting the Other Connectors
4.8.1
Serial Communications Connector (CN3)
To use a Digital Operator, connect it to CN3 on the SERVOPACK.
Refer to the following manual for the operating procedures for the Digital Operator.
Σ
-7-Series Digital Operator Operating Manual (Manual No.: SIEP S800001 33)
4.8.2
Computer Connector (CN7)
To use the S Engineering Tool, connect the computer on which the S is
installed to CN7 on the SERVOPACK.
Refer to the following manual for the operating procedures for the S.
Engineering Tool S Online Manual (Manual No.: SIEP S800001 48)
4.8.3
Analog Monitor Connector (CN5)
To use an analog monitor, connect CN5 on the SERVOPACK.
•
Wiring Example
*
The measuring instrument is not provided by Yaskawa.
Refer to the following section for information on the monitoring methods for an analog monitor.
9.3 Monitoring Machine Operation Status and Signal Waveforms
Use the Yaskawa-specified cables. Operation will not be dependable due to low noise resistance
with any other cable.
Important
Measuring probe
Measuring
instrument
*
Measuring probe
White
Red
Black
Black
Probe ground
Probe ground
White
Red
Black
Connect to CN5
on the SERVOPACK.
Black