4.3 Wiring the Power Supply to the SERVOPACK
4.3.2 Wiring Procedure for Main Circuit Connector
4-14
•
Single-Phase, 100-VAC Power Supply Input
You can use a single-phase, 100-VAC power supply input with the following models.
•
SGD7S-R70F, -R90F, -2R1F, and -2R8F
4.3.2
Wiring Procedure for Main Circuit Connector
•
Required Items
1.
Remove the main circuit connector and motor connector from the SERVOPACK.
2.
Remove the sheath from the wire to connect.
Terminal
Symbols
Terminal Name
Specifications and Reference
L1, L2
Main circuit power supply
input terminals for AC
power supply input
Single-phase, 100 VAC to 120 VAC, -15% to +10%,
50 Hz/60 Hz
L1C, L2C
Control power supply termi-
nals
Single-phase, 100 VAC to 120 VAC, -15% to +10%,
50 Hz/60 Hz
B1, B2
Regenerative Resistor termi-
nals
4.3.5 Wiring Regenerative Resistors
If the regenerative capacity is insufficient, connect an External
Regenerative Resistor between B1/
and B2. The External
Regenerative Resistor is not included. Obtain it separately.
Required Item
Remarks
Spring Opener or Flat-
blade Screwdriver
•
Spring Opener
SERVOPACK accessory
(You can also use model 1981045-1 from Tyco Electronics Japan G.K.)
•
Flat-blade screwdriver
Commercially available screwdriver with tip width of 3.0 mm to 3.5 mm
Servomotor connector
Main circuit
connector
Enlarged View
Locks
1. Press in on
the lock.
2. Press in on the
locks to remove
the connectors.
8 mm to 9 mm