7.4 Trial Operation from the Host Controller for the Servomotor without a Load
7-10
7.4
Trial Operation from the Host Controller for the Servomotor without a Load
Conform the following items before you start trial operation from the host controller for the Ser-
vomotor without a load.
•
Make sure that the Servomotor operation reference from the host controller to the SERVO-
PACK and the I/O signals are set up properly.
•
Make sure that the wiring between the host controller and SERVOPACK and the polarity of
the wiring are correct.
•
Make sure that all operation settings for the SERVOPACK are correct.
The operation sequence for trial operation from the host controller for the Servomotor without a
load is given below.
Preparation
s
Trial Operation with
S
peed Control
Trial Operation with Po
s
ition Control
Po
s
ition Control from the Ho
s
t Controller
Trial Operation with the Machine and
S
ERVOPACK
Refer to the following
s
ection for detail
s
.
Trial Operation for Different
Control Method
s
Check the connection
s
and
s
tatu
s
of the input
s
ignal circuit
s
.
Analog
7.4.1 Preparing the Servomotor for Trial Operation
7.4.2 Trial Operation for Speed Control
7.4.4 Trial Operation for Position Control
7.5 Trial Operation with the Servomotor Connected to the Machine