F1-10: Speed Deviation Detection Level
No.
(Hex.)
Name
Description
Default
(Range)
F1-10
(0389)
Speed Deviation Detection
Level
Sets the detection level of
dEv [Speed Deviation]
as a percentage when the maximum output
frequency is 100%.
10%
(0 - 50%)
When the speed deviation between the frequency reference and the actual motor speed is more than the value set
in
F1-10
for longer than the time set in
F1-11 [Speed Deviation Detect DelayTime]
, the drive will detect
dEv
.
■
F1-11: Speed Deviation Detect DelayTime
No.
(Hex.)
Name
Description
Default
(Range)
F1-11
(038A)
Speed Deviation Detect
DelayTime
Sets the length of time that the difference between the frequency reference and speed feedback
must be more than the level in
F1-10
to cause
dEv [Speed Deviation]
.
0.5 s
(0.0 - 10.0 s)
When the speed deviation between the frequency reference and the actual motor speed is more than the value set
in
F1-10 [Speed Deviation Detection Level]
for longer than the time set in
F1-11
, the drive will detect
dEv
.
■
F1-12: Encoder 1 Gear Teeth 1
No.
(Hex.)
Name
Description
Default
(Range)
F1-12
(038B)
Encoder 1 Gear Teeth 1
Sets the number of gear teeth on the motor side. This parameter and
F1-13 [Encoder 1 Gear Teeth
2]
set the gear ratio between the motor and encoder.
0
(0 - 1000)
After you set the number of gear teeth, the drive uses this formula to calculate the motor speed:
Note:
When
F1-12 = 0
or
F1-13 = 0
, the gear ratio is 1.
■
F1-13: Encoder 1 Gear Teeth 2
No.
(Hex.)
Name
Description
Default
(Range)
F1-13
(038C)
Encoder 2 Gear Teeth 1
Sets the number of gear teeth on the load side. This parameter and
F1-12 [Encoder 1 Gear Teeth
1]
set the gear ratio between the motor and encoder.
0
(0 - 1000)
After you set the number of gear teeth, the drive uses this formula to calculate the motor speed:
Note:
When
F1-12 = 0
or
F1-13 = 0
, the gear ratio is 1.
■
F1-14: Encoder Open-Circuit Detect Time
No.
(Hex.)
Name
Description
Default
(Range)
F1-14
(038D)
Encoder Open-Circuit
Detect Time
Sets the detection time for
PGo [Encoder (PG) Feedback Loss]
.
2.0 s
(0.0 - 10.0 s)
PGo
is detected when the drive does not detect output pulses from the encoder for an amount of time longer than
or equal to the value set in
F1-14
.
Note:
Faults such as
ov [Overvoltage]
and
oC [Overcurrent]
may occur depending on the motor speed and load conditions.
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...