12.2 A: Initialization Parameters
460
YASKAWA
SIEPC71061753A GA500 Technical Manual
No.
Name
o2-04
Drive Model (KVA) Selection
q1-xx - q8-xx
DriveWorksEZ Parameters
r1-xx
DWEZ Connection 1-20
Note:
•
Set
A1-06 [Application Preset]
to let the drive automatically set the best parameter settings for the selected application. The drive does
not initialize
A1-02
when
A1-03 = 2220, 3330
.
•
When
A1-03 = 2220, 3330
, the drive automatically set
A1-05 [Password Setting] = 0000
. Make sure that you set the password again
for applications where a password is necessary.
■
A1-04: Password
No.
(Hex.)
Name
Description
Default
(Range)
A1-04
(0104)
Password
Entry point for the password set in
A1-05 [Password Setting]
. The user can view the settings of
parameters that are locked without entering the password. Enter the correct password in this
parameter to change parameter settings.
0000
(0000 - 9999)
If the password entered in
A1-04
does not agree with the password setting in
A1-05
, you cannot change these
parameters:
•
A1-01 [Access Level Selection]
•
A1-02 [Control Method Selection]
•
A1-03 [Initialize Parameters]
•
A1-06 [Application Preset]
•
A1-07 [DriveWorksEZ Function Selection]
•
A2-01 to A2-32 [User Parameter 1 to 32]
To lock parameter settings after making changes without changing the password, enter the incorrect password in
A1-04
and push
.
Enter the Password to Unlock Parameters
Use this procedure to unlock parameter settings.
Set the password in
A1-05 [Password Setting]
, and show the Parameter Setting Mode screen on the keypad.
This procedure verifies the password, and makes sure that the parameter settings are unlocked.
1.
Push
or
to select “A: Initialization Parameters”, then push
.
2.
Push
or
to select
[A1-04]
, then push
.
You can now change parameter settings.
3.
Push
or
to move the digit and enter the password.
4.
Push
to confirm the password.
The drive unlocks the parameters and automatically shows the Parameters Screen.
5.
Push
or
to show
[A1-02]
, then push
.
The keypad shows the setting value for
[A1-02]
.
6.
Push
or
to make sure that you can change the setting value.
Push
(Back) until the keypad shows the Parameter Setup Mode screen.
■
A1-05: Password Setting
No.
(Hex.)
Name
Description
Default
(Range)
A1-05
(0105)
Password Setting
Set the password to lock parameters and prevent changes to parameter settings. Enter the correct
password in
A1-04 [Password]
to unlock parameters and accept changes.
0000
(0000 - 9999)
This parameter can lock these parameter settings:
•
A1-01 [Access Level Selection]
•
A1-02 [Control Method Selection]
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание CIPR-GA50C series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 157: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 157...
Страница 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 159: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 159...
Страница 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 454: ...11 22 Parameters Changed by PM Motor Code Selection 454 YASKAWA SIEPC71061753A GA500 Technical Manual...