No.
Parameter Name
Default Setting
b6-01
Dwell Reference at Start
3.0 Hz
b6-02
Dwell Time at Start
0.3 s
C1-01
Acceleration Time 1
3.0 s
C1-02
Deceleration Time 1
3.0 s
C6-01
Drive Duty Selection
0: Heavy Duty
C6-02
Carrier Frequency Selection
2: 5 kHz
d1-01
Frequency Reference 1
6.0 Hz
d1-02
Frequency Reference 2
30.0 Hz
d1-03
Frequency Reference 3
60.0 Hz
E1-03
V/f Pattern Selection
0FH
H2-02
Terminals P1 Function Selection
37: During Frequency Output
H2-03
Terminals P2 Function Selection
5: Frequency Detection 2
L2-03
Momentary Power Loss Minimum Baseblock Time
0.3 s
L3-04
Momentary Power Loss Voltage Recovery Ramp Time
0: Disabled
L4-01
Speed Agreement Detection Level
2.0 Hz
L4-02
Speed Agreement Detection Width
0.0 Hz
L6-01
Torque Detection Selection 1
8: UL3 at RUN - Fault
L6-02
Torque Detection Level 1
5%
L6-03
Torque Detection Time 1
0.5 s
L8-05
Input Phase Loss Protection Selection
1: Enabled
<1>
L8-07
Output Phase Loss Protection Selection
1: Enabled
L8-38
Carrier Frequency Reduction
1: Enabled below 6 Hz
L8-41
High Current Alarm Selection
1: Enabled (alarm is output)
<1> Disable L8-05 for single-phase models.
Table 4.16 Preset 6: User Parameters (A2-01 to A2-16):
No.
Parameter Name
No.
Parameter Name
A1-02
Control Method Selection
d1-02
Frequency Reference 2
b1-01
Frequency Reference Selection 1
d1-03
Frequency Reference 3
b6-01
Dwell Reference at Start
E1-08
Middle Output Frequency Voltage
b6-02
Dwell Time at Start
H2-01
Terminals MA, MB, and MC Function Selection
C1-01
Acceleration Time 1
L1-01
Motor Overload Protection Selection
C1-02
Deceleration Time 1
L4-01
Speed Agreement Detection Level
C6-02
Carrier Frequency Selection
L6-02
Torque Detection Level 1
d1-01
Frequency Reference 1
L6-03
Torque Detection Time 1
u
Notes on Controlling the Brake when Using Application Preset 6
The frequency detection function is used for controlling the brake.
When an external Baseblock command is present while a Run command is active, the frequency reference will be kept as long
as the Run command is active. To avoid improper brake operation make sure that frequency detection is set so that the brake
does not open during Baseblock (L4-07 = “0”, default).
The table below shows how to set up the drive when using output terminals P2-PC as brake control output.
Brake Open/Close
Brake Activation Level
Control Mode
Function
Parameter
Signal
Parameter
V/f
OLV
OLV for
PM
Frequency
Detection 2
L4-07 = 0
Frequency Detection Level
L4-01 = 1.0 to 3.0 Hz
<1>
O
O
−
H2-03 = 5
Frequency Detection Width
L4-02 = 0.0 to 0.5 Hz
<2>
4.6 Application Selection
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual
99
4
Start-Up Programming & Operation