No.
Name
Description
Range
Def.
Control
Mode
Addr.
Hex
Pg.
V/
f
O
L
V
P
M
F6-25
<7>
Operation Selection at
MECHATROLINK
Watchdog Timer Error (E5)
0: Ramp to stop. Decelerate using the deceleration time in
C1-02.
1: Coast to stop
2: Fast stop. Decelerate using the deceleration time in C1-09.
3: Alarm only
0 to 3
1
A A A
3C9
–
F6-26
<7>
MECHATROLINK bUS
Errors Detected
Sets the number of option communication errors (bUS).
2 to 10
2
A A A
3CA
–
F6-30
PROFIBUS node address
Sets the node address for a PROFIBUS option.
0 to 125
0
A A A
3CB
–
F6-31
PROFIBUS Clear Mode
Selection
Selects the operation when a "Clear Mode" command is
received.
0: Resets drive operation.
1: Maintains the previous operation state.
0, 1
0
A A A
3CC
–
F6-32
PROFIBUS Data Format
Selections
0: PPO Type
1: Conventional
0, 1
0
A A A
3CD
–
F6-35
CANopen Node ID selection Sets the Node ID for a CANopen option
<2>
99
A A A
3D0
–
F6-36
CANopen Communications
speed
0: Auto-adjust
1: 10 kbps
2: 20 kbps
3: 50 kbps
4: 125 kbps
5: 250 kbps
6: 500 kbps
7: 800 kbps
8: 1 Mbps
0 to 8
6
A A A
3D1
–
F6-40
CompoNet Node ID
Sets the Node ID for a CompoNet option.
0 to 63
0
A A A
3D5
–
F6-41
CompoNet Speed
0: 93.75 kbps
1: Reserved
2: 1.5 Mbps
3: 3 Mbps
4: 4 Mbps
5-255: Reserved
0 to 255
0
A A A
3D6
–
F6-50
<3>
DeviceNet MAC Address
Selects the drives MAC address for DeviceNet.
0 to 64
64
A A A
3C1
–
F6-51
<3>
Device Net Communications
Speed
0: 125 kbps
1: 250 kbps
2: 500 kbps
3: Adjustable from Network
4: Detect automatically
0 to 4
4
A A A
3C2
–
F6-52
<3>
DeviceNet PCA setting
I/O Polled Consuming Assembly Data Instance
0 to 255
21
A A A
3C3
–
F6-53
<3>
DeviceNet PPA setting
I/O Polled Producing Assembly Data Instance
0 to 255
71
A A A
3C4
–
F6-54
<3>
DeviceNet Idle Mode Fault
Detection
Selects if an EF0 fault is detected when no data are received
from the master.
<4>
0: Detection enabled
1: No detection
0, 1
0
A A A
3C5
–
F6-55
DeviceNet Baud Rate
Monitor
Verifies the baud rate running on the network.
0: 125 kbps
1: 250 kbps
2: 500 kbps
0 to 2
0
A A A
3C6
–
F6-56
<3>
DeviceNet Speed Scaling
Factor
Sets the scaling factor for the speed monitor in DeviceNet
Class ID 2AH Object.
-15 to 15
0
A A A
3D7
–
F6-57
<3>
DeviceNet Current Scaling
Factor
Sets the scaling factor for the output current monitor in
DeviceNet Class ID 2AH Object.
-15 to 15
0
A A A
3D8
–
F6-58
<3>
DeviceNet Torque Scaling
Factor
Sets the scaling factor for the torque monitor in DeviceNet
Class ID 2AH Object.
-15 to 15
0
A A A
3D9
–
F6-59
<3>
DeviceNet Power Scaling
Factor
Sets the scaling factor for the power monitor in DeviceNet
Class ID 2AH Object.
-15 to 15
0
A A A
3DA
–
B.2 Parameter Table
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual
373
B
Parameter List