38
39
Suitable location for
the charging station
Connector B, red
1 m extra wire
for potential
adjustment
Connector
F, black
NO
OK
Only use the included waterproof boundary wire connectors (17) to join together two
pieces of boundary wire.
See below for some further sketches giving more distance guidelines.
Avoid right angles when running the boundary wire around a corner. Instead,
separate into two 45° angles.
In case the included boundary wire is too short for your garden, more is available from our
service provider.
The wire's total length must not exceed 300 m.
10 - 15 mm
Prepare the boundary wire for the charging station
Use a wire stripper to remove 10-15 mm insulation from each end. Twist the threads
tight.
NOTE !
If the enclosed working area is less than 100 m
2
or the total total boundary wire
length is less than 40m, connect a 10 Ω / 20 W cement resistance to the boundary wire.
Connect the charging station to the boundary wire
Place the charging station on the end of the boundary wire so that the wire runs lengthwise below
the middle of the charging station. Connect that end to the left (black) connector marked "F"
(front). Connect the other end to the right (red) connector marked "B" (back).
F (black)
B (red)
IMPORTANT INFORMATION
Double check that the charger connections are as shown below. Even if there is a blue light, if
the connectors are wrongly connected the machine will not work.
ASSEMBLY INSTRUCTIONS
ASSEMBLY INSTRUCTIONS