2. Inspection and Adjustment
38
2.3 Adjusting the no-load maximum or minimum speed
1) After warming the engine up, gradually raise the
speed and set it at the no-load maximum speed.
2) If the no-load maximum speed is out of the
standard, adjust it by turning the high idle limiting
bolt.
3) Then set the no-load minimum speed by adjusting
the low idle limiting bolt.
2.4 Sensor Inspection
2.4.1 Oil pressure switch
Disconnect the connector from the oil pressure switch.
Keep the voltammeter probes in contact with the switch
terminal and cylinder block while operating the engine.
It is abnormal if circuit is closed.
2.4.2 Thermo switch
Place the thermo switch in a container filled with
antifreeze or oil. Heat it while measuring the fluid
temperature. The switch is normal if the voltammeter
shows continuity when the fluid temperature is 97-103
deg C.
Standards
(Unit : min
-1 )
No-load maximum
No-load minimum
3325
±
25
800
±
25
Remote
control cable
Fuel injection pump
Cable joint
High speed
limiting bolt
Low speed limiting bolt
Control lever
(Continuity test)
Tester probes
Oil pressure switch
Cylinder block
(flywheel side)
Thermometer
Thermo switch
Hot water
Tester probes