background image

Infrared signal

receiver

Manual Switch

Nixie tube

Running light

Timing light

D e f ro s t i n g/
preheat light

warning light

Buzzer

DISPLAY PANEL

 

 

Infrared signal receiver

: receive the signal from the remote controller.

To make your remote controller operation more efficient, please let

 

remote controller

emitt

 

or aim at infrared signal receiver.

Buzzer: firstly power supplied or any of remote controller operations will make the buzzer

 

sound once.

Some obstacles occuring in the system will be recognized by intelligent recognition

system of unit ,lighting on the DISPLAY PANEL flashing show the type of obstacles .

DISPLAY PANEL

1. It suits for Body dimension :840X245X840

 

or 840X290X840 cooling and heating pump type.

2. It suits for Body dimension :580X255X580 cooling and heating pump type.

LIGHTING ON

Timer indicator

Operation indicator

PRE-DEF indicator

Pump indicator

INFRARED SIGNAL

RECEIVER

ON when preset time for switching ON/OFF the unit

ON when the unit is power on

ON when the water level is high

ON when the unit prevent cool air flowing in room.

Timer indicator

Operation indicator

PRE-DEF indicator

Pump indicator

The cooling function allows the air conditioner to cool the room and at
the same time reduces the humidity in the air.

To activate the cooling function ( COOL ) , press the MODE button
until the symbol

appears on the display.

The cooling cycle is activated by setting the keys

or

at a

temperature lower than that of the room.
To optimize the functioning of the conditioner, adjust the temperature (1) ,

the speed (2) and the direction of the air flow (3) by pressing the keys
indicated

COOLING MODE

1

2

3

HEATING MODE

The heating function allows the air conditioner to produce hot air.
To activate the heating function ( HEAT ) , press the

MODE button until the symbol

appears on the display.

With the keys

or

set a temperature higher than that of the room..

To optimize the functioning of the conditioner adjust the temperature ( 1 ),
the speed ( 2 ) and the direction of the air flow ( 3 ) by pressing the keys

indicated

The appliance is fitted with a Hot Start function, which delays
appliance to startup in a few seconds to ensure an immediate

output of hot air.
In HEATING operation, the appliance can automatically activate a

defrost cycle, which is essential to free the condenser from an
excessive deposit of frost .This procedure usually lasts for 2-10

minutes during defrosting,fans stop operation. After defrosting ,it
returns to HEATING mode automatically.

1

2

3

FEEL mode indicator

10

MIDDLE FAN SPEED indicator

COOLING indicator

11

HIGH FAN SPEED indicator

DEHUMIDIFYING indicator

12

SLEEP indicator

AUTO FAN indicator

17

BATTERY indicator

LOW FAN SPEED indicator

18

CLOCK indicator

FAN ONLY OPERATION indicator 13

SUPER indicator

HEATING indicator

14

HEALTHY indicator

TIMER OFF indicator

15

ECO indicator

ECO

TIMER ON indicator

16

BATTERY indicator

Meaning

1

2
3

8

9

4
5

6
7

No. Symbols

Meaning

No.

Symbols

Remote control DISPLAY
Meaning of symbols on the liquid crystal display

5

Содержание YC12T1/I

Страница 1: ...85008 008702 TCC 24CHRH DVI 02 80g m GB T1804 c A K100 1 2 3 4 5 5 1 1 A5 85008 008702 8 1 C GG 2308 0454...

Страница 2: ...INVERTER YC12T1 I YC12T1 O YC12T1 P YC18T1 I YC18T1 O YC18T1 P YC24T1 I YC24T1 O YC24T1 P YC42T1 I YC42T1 O YC42T1 P YC48T1T I YC48T1T O YC48T1T P YC55T1T I YC55T1T O YC55T1T P...

Страница 3: ...e repairing the air conditioner please first read the technical service manual Compared with common refrigerant R32 is an environmental friendly refrigerant that has no harm to the ozone layer and wea...

Страница 4: ...01 03 04 05 06 13 15 16 18 21 26 27 29 32...

Страница 5: ...to this installation instructions strictly If installation is defective it will cause water leakage electrical shock or fire Use the attached accessories parts and specified parts for installation Oth...

Страница 6: ...ary to preheat the indoor heat exchanger at the beginning of HEATING operation lest cold air be discharged In HEATING operation the appliance will defrost automatically This procedure lasts 2 10 minut...

Страница 7: ...n lasting for about one diel only please do not cut off the electricity supply it is necessary to heat the crankcase heater so as to avoid force start of compressor Notice that the air inlet outlet mu...

Страница 8: ...indoor unit or outlet of oudoor unit any of blocks will reduce cooling or heating efficiency FUNCTION AND OPERATION OF PANEL S PARTS 1 PANEL 2 AIR FLOW LOUVER 3 INFRARED SIGNAL RECEIVER 4 DISPLAY PANE...

Страница 9: ...ing in the system will be recognized by intelligent recognition system of unit lighting on the DISPLAY PANEL flashing show the type of obstacles DISPLAY PANEL 1 It suits for Body dimension 840X245X840...

Страница 10: ...on the ceiling has been decided Confirm sizes of the indoor unit and ceiling opening with the attached installation paper pattern Please fix the paper pattern below the body with M5X16 screws 4 Please...

Страница 11: ...where can not bear the weight of the machine e In kitchen where it is full of oil gas f There is strong electromagnetic wave existing g There is acid or alkaline liquid evaporating h A place where air...

Страница 12: ...horl is to be used The center distance between the bolts is decided by the size of the unit Use the following method to install Installation method should be changed under the different construction s...

Страница 13: ...mbedding screw bolt Pipe hanging and embedding screw bolt Install the supporting angle steel Steel roof beam structure Bolt Overhanging the indoor unit Adjust the gasket down side to 90mm over the cei...

Страница 14: ...iring Be sure that the indoor unit and ceiling hole installation size is right before installation Be sure to seal the connection parts between and the panel the indoor unit or even small gaps may cau...

Страница 15: ...he polyvinyl chloride pipe Use polyvinyl chloride glue at the connection part of the drainage pipe be sure no water leakage Paste glue at the front 40mm of the polyvinyl chloride pipe insert it into t...

Страница 16: ...AC of terminal 4 After drain pump run 2 min reset the water level pin and the drain pump motor will stop after min L N Motor Sound Test The drainage test is doing during checking the drain pump motor...

Страница 17: ...ase connect step motor wire display board wire to the electrical box according to ELECTRIC WIRING DIAGRAM on theelectrical 1 Please screw M10 gasket and M6 20 bolt at the corner of indoor unit before...

Страница 18: ...box aligns the one on the panel 2 Please connect step motor wire display board wire to the electrical box according to ELECTRIC WIRING DIAGRAM on the electrical box 3 Then screw the other two M6 20 b...

Страница 19: ...5 A A B C 780 516 314 845 574 348 375 342 358 700 Figure of body size Unit 910 607 390 421 910 607 390 421 378 804 378 804 mm 436 858 436 1010 660 462 494 1010 660 462 494 391 391 440 440 858 15 845 5...

Страница 20: ...ver 3 After connecting from the valve gap reinstall it from left right or backwards for installation 4 The right picture is the sketch map of valve installation board of outdoor Gas side low pressure...

Страница 21: ...tioner The attached plug is equipped with grounding pin and it must not be modified as desired Please adopt the fuse or circuit breaker prescribed in Installation Instructions Only qualified electrici...

Страница 22: ...ide Liquid side Model 12 18K 24K 30 36 42 48 55K 6 35 7 16inch 9 52 5 8inch 12 7 3 4 inch 6 35 7 16inch 3 8 9 52 5 8inch 15 88 7 8inch Liquid pipe diameter Additional charge for 1m pipe R32 0 016kg 0...

Страница 23: ...low pressure valve muse be manipulated as follow Burr Pipe Diameter Please refer to operation manual for the usage of manifold valve Stengthen to fasten the torch High pressure valve Low presasure val...

Страница 24: ...o vacuum from the gas side refrigerant adding mouth of the outdoor unit Don t use the refrigerant of the outdoor unit to do the vacuum A certain volume of refrigerant had been added into the outdoor u...

Страница 25: ...ay occur the appliance must be positioned so that the plug is accessible the appliance shall be installed in accordance with national wiring regulations CAUTION ELECTRIC WIRING The temperature of refr...

Страница 26: ...ver Sensor connecting wire Power supply wire Signal connecting wire Notice Drain pipe must not be flattened during binding treatment Drain pipe outlet should be led to a place that can avoid affecting...

Страница 27: ...L N B A E TB1 POWER SUPPLY INDOOR UNIT 3 1 0mm 2 B A E L1 L2 L3 L3 TB2 POWER SUPPLY 5 2 5mm 2 3 0 5mm Signalcablewithshield 2 OUTDOOR UNIT 48 55K...

Страница 28: ...d installation instructions carefully 2 Do not let air in or refrigerant out during installing or reinstalling the appliance 3 Test run the air conditioner after finishing installation and keep the re...

Страница 29: ...ust be increased If the accumulated dust is too heavy to be cleaned please replace the filter with a new one replaceable air filter is an optional fitting 1 Open the air in grill Push the grill switch...

Страница 30: ...he air conditioner be sure to disconnect the power supply plug because it may damage or fade the surface of the unit Do not use benzine thinner polishing powder or similar solvents for cleaning These...

Страница 31: ...y while the air conditioner is in use especially if there is also a gas appliance in use in this room Failure to follow these directions may result in a loss of oxygen in the room WARNING To prevent e...

Страница 32: ...is auto matically controlled with elapsed time so that the room isn t too cool during cooling or too warm during heating About power off memory function When the air conditioner disconnect the power...

Страница 33: ...ilure 1 rror b E Hardware E PCB and display screen communication failure rror C 1 Outdoor modules Communication failure 3 E Hardware Error E 1 Outdoor EEPROM fault 4 E Hardware Error F 1 Outdoor DC fa...

Страница 34: ...l load 8 P Others Error A 2 Communication failure mode conflict 9 F Others Error 0 3 Infrared human sensing sensor failure 3 F Remote control display adjustment 1 3 Battery module failure 4 F Remote c...

Страница 35: ...freezing protection limit frequency reduction 0 F Remote control display adjustment j 5 Exhaust protection limit frequency reduction 1 F Remote control display adjustment n 5 External AC current prote...

Страница 36: ...on area The minimum area for installation is determined by charging quantity additional charging quantity 2 Checking out in the applicable tables 1 For indoor unit confirm the model of indoor unit and...

Страница 37: ...3 0 77 2 3 2 6 54 3 2 9 76 3 2 87 9 3 4 7 38 3 4 11 0 3 4 99 2 3 6 8 27 3 6 12 4 3 6 111 3 8 9 22 3 8 13 8 3 8 124 4 0 10 2 4 0 15 3 4 0 137 4 2 11 3 4 2 16 8 4 2 151 4 4 12 4 4 4 18 5 4 4 166 4 6 13...

Страница 38: ...ASTON COM S A Str Linia de Centura nr 46 VGP Park Bucharest Cladirea C Sat Stefanestii de Jos Comuna Stefanestii de Jos judet Ilfov 077175 Romania...

Отзывы: