manualshive.com logo in svg
background image

 

 

Vapor Temperature Indicator 

for Rotary Evaporator 

Model 

TA300

 

Instruction Manual 

 

- Second Edition -

 

This document is the exclusive instruction manual to the vapor temperature 
indicator TA300 model installed on the RE300 model rotary evaporator. 
Please use this document together with the instruction manual of the rotary 
evaporator as for the operating instructions of device. 

 

 

Yamato Scientific Co. LTD. 

 

This paper has been printed on recycled paper.

z

 Thank you for purchasing "vapor temperature 

indicator, TA300" of Yamato Scientific Co., Ltd. 

z

 To use this unit properly, read this "Instruction 

Manual" thoroughly before using this unit. 
Keep this instruction manual around this unit for 
referring at anytime. 
 

WARNING!: 

Carefully read and thoroughly understand the 
important warning items described in this 
manual before using this unit.

Содержание TA300

Страница 1: ... rotary evaporator as for the operating instructions of device Yamato Scientific Co LTD This paper has been printed on recycled paper z Thank you for purchasing vapor temperature indicator TA300 of Yamato Scientific Co Ltd z To use this unit properly read this Instruction Manual thoroughly before using this unit Keep this instruction manual around this unit for referring at anytime WARNING Careful...

Страница 2: ...ily Inspection and Maintenance 6 Long storage and disposal 7 When not using this unit for long term When disposing 7 In the Event of Failure 8 Safety Device and Error Code 8 Trouble Shooting 8 After Service and Warranty 9 Specification 10 Wiring Diagram 10 Replacement Parts Table 11 Reference 12 List of Dangerous Substances 12 Installation Standard Manual 13 ...

Страница 3: ...Resin attaching screw to glass unit and silicone packing are attached 5 Instruction manual 1 Installation Method 1 Fixation of TA300 Unpack the unit and install it at level area Tear the seal from screw hole of RE main body Cover RE main body by the Bracket vacuum controller Fix the Bracket vacuum controller by flat head screw M4 and tapping screw M4 Slide the VR main body that fixing ditch of VR ...

Страница 4: ...2 ...

Страница 5: ...er Hose piping is not required 3 Sensor wiring Connect the sensors to the sensor terminals of corresponding number respectively by using a cross slot screwdriver Temperature sensor TA300 To back surface of RE main unit To connector on the back surface of main unit Condenser A Condenser B Condenser C A B b A B b Sensor terminals on the back surface Sensor ...

Страница 6: ...4 Appearance Diagram A B b Rear view Front view Power cord with connector DC 24V input Sensor connecting terminals Temperature display screen Power switch ...

Страница 7: ...on the power of RE main unit and start operation 2 Turn on the power switch of operation panel on the TA300 The screen displays the current evaporating temperature by in increments of 0 1 Temperature display screen Power switch ...

Страница 8: ...not recommended Do not disassemble or modify this unit Do not disassemble or modify this unit Fire or electrical shock or failure may be caused CAUTION During a thunder storm During a thunderstorm turn off the power switch immediately and then disconnect the power cord If this procedure is not followed fire or electrical shock may be caused Maintenance Method Daily Inspection and Maintenance For t...

Страница 9: ...nit as possible and recycle the reusable parts considering to the environmental protection The feature components of this unit and materials used are listed below Component Name Material Exterior Parts Outer covering ABS resin Electrical Parts Switches Composite of resin copper and other Display unit Composite of ABS resin glass fiber and other Power cord and connector Composite of resin coating c...

Страница 10: ...or service Sensor trouble detection Contact failure of sensor Make a call for service Trouble Shooting Phenomenon Check point Device does not start after turning on the power switch Check if the power source is turned to on Check if the power cable is securely plugged Check if a power failure occurs In the case if the error other than listed above occurred turn off the power and disconnect the pow...

Страница 11: ...les office Check following items before contact Model Name of Product Production Number Purchase Date About Trouble in detail as possible Minimum Retention Period of Performance Parts for Repair The minimum retention period of performance parts for repair of this unit is 7 years after discontinuance of this unit The performance part for repair is the part that is required to maintain this unit See...

Страница 12: ...oating resin nut attached Display part LED display Outer covering ABS resin coating Temperature display range 199 to 500 Performance Function Temperature display resolution 0 1 External dimensions W D H projection is not included Standard Power supply DC 24V 0 5A and below Wiring Diagram Symbol Name CN1 Connector CN2 Relay connector SW Power switch TTM 004 Temperature display unit TH1 Pt100Ω T Ter...

Страница 13: ...Power switch LT00015364 AB6M A1B Izumi Denki Temperature display unit LT00015091 TTM 004 DC24V Toho Denshi Vapor temperature sensor LT00015090 Pt100Ω Yamato Scientific Sensor cap LT00015054 Duracon Yamato Scientific Sensor packing LT00015054 Silicon rubber Yamato Scientific ...

Страница 14: ...um perchlorate and other perchlorate Potassium peroxide Sodium peroxide Barium peroxide and other inorganic peroxide Potassium nitrate Sodium nitrate Ammonium nitrate and other nitrate Sodium chlorite and other chlorites OXIDIZING Calcium hypochlorite and other hypochlorites Ethyl ether Gasoline Acetaldehyde Propylene chloride Carbon disulfide and other flammable substances having a flash point of...

Страница 15: ...art of operation Start operation Handling Precautions P 6 Description 1 Description of operation Explain the operation of each unit to the customer according to this Operation Manual All 2 Error code Explain error codes and the procedure for resetting them to the customer according to this Operation Manual In the Event of Failure P 8 3 Maintenance inspection Explain the operation of each unit to t...

Страница 16: ...Unexpected accidents or breakdown may result in Note The contents of this document may be changed in future without notice Any books with missing pages or disorderly binding may be replaced Instruction Manual for Vapor Temperature Indicator for Rotary Evaporator Model TA300 First Edition Feb 10 2006 Second Edition Dec 26 2008 Revised Feb 8 2012 Yamato Scientific Co Ltd 2 1 6 Nihonbashi Honcho Chuo...