Yamato SG Series Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

 COMPACT GLOVE BOX

 

 

Model

  

SG828/835/848/860 

 

 

 

 

 

 

 

Instruction Manual 

- February 2022 – 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 Thank you for purchasing the Compact Glove 

Box SG828/835/848/860, of Yamato Scientific. 

 To use this unit properly, read this "Instruction 

Manual" thoroughly before using the unit. 

Keep this instruction manual around this unit for 

reference at any time. 

 

 WARNING: 

Carefully read and thoroughly understand the 

important warning items described in this 

manual before using this unit. 

Содержание SG Series

Страница 1: ...SG828 835 848 860 of Yamato Scientific To use this unit properly read this Instruction Manual thoroughly before using the unit Keep this instruction manual around this unit for reference at any time W...

Страница 2: ...on 5 Set Up Procedures 7 Purging Main Chamber 8 Using the Transfer Chamber 9 General Maintenance Schedule 10 Glove Change Out Procedure 11 Sterilization Cleaning 12 Replacement Parts and Accessories 1...

Страница 3: ...eplace the ambient room atmosphere with alternative choices such as NITROGEN ARGON PLASMA or other inert type gases The units are shipped as complete systems Nothing needs to be added except your gas...

Страница 4: ...apor WARNING DO NOT EXCEED THE 10 LEVEL OF HYDROGEN NOTE When using Basic or Compact Glove Boxes it is not necessary to use the 10 Hydrogen mix The Hydrogen addition is for Controlled Atmosphere chamb...

Страница 5: ...minimized The top section is removable to allow for insertion of large pieces of equipment such as Top Loaders and Analytical Balances CHAMBER FEATURES Standard features included with the glove box a...

Страница 6: ...ion containing small HEPA filter Section containing carbon materials Replace by merely screwing into threaded base Diameter of this small filteris about 3 This small filter should be replaced about ev...

Страница 7: ...6 Filter Information Close up pressure relied pop valve Part no PLA HW3126 Close up view of new filter mounted inside Part no PLA 830ABC...

Страница 8: ...tion as when you removed it Make sure the holes line up and both the top and bottom section are aligned properly Be careful not to cross thread the knobs At first only partially tighten each knob usin...

Страница 9: ...nect a small vacuum pump to the key cock valve on the upper left side of the glove box For vacuum pump data refer to Glove Box Accessories on page twelve 12 STEP 2 Set the incoming gas source OR cylin...

Страница 10: ...m valve and push the button to turn on the vacuum chamber pump Draw a vacuum down to 18 to 20 of Hg Watch the vacuum gauge When that level is reached turn off the vacuum pump and close the vacuum valv...

Страница 11: ...n house protocol Monthly Check gloves and gasketing for excessive wear and tear Check to see if any clamps need adjusting Semi Annually Perform your standard main chamber leak test Annually Replace th...

Страница 12: ...use the glove port plug if the glove box is shut down for periodic cleaning 2 Remove the old yellow vinyl tape and stainless steel worm gear clamp 3 Remove the old damaged glove NOTE You may want to...

Страница 13: ...s include Novus Plastic Polish 1 Brillianize cleaner and Rez N Kleen In general aromatic and chlorinated hydrocarbons will attack most plastic surfaces This applies to all plastics used in our chamber...

Страница 14: ...ug pair PLA 800PUMP Vacuum Diaphragm Pump with 5 hose on intake sideOpen Flow 1 1 CFM 31 LPM 115 Volt 60Hz PLA 800PUMP EXP 220 Volt 50Hz PLA 800AS SPI Work Station Ionizer Effectively eliminates all s...

Страница 15: ...oors 500 thick clear cast acrylic Gaskets 500 neoprene Clamps Rivets type 430 stainless steel Stamped parts 302 304 stainless steel Handle PVC Hinges Fasteners 18 8 type stainless steel Pop Valve Body...

Страница 16: ...sible and will not be held liable for damage and or injury caused using our products Product Return Policy If you are not satisfied with your purchase and wish to make a return contact our customer se...

Страница 17: ...nduct what this document forbids as unexpected accidents or breakdown may result Instruction Manual for Compact Glove Boxes Model SG828 835 848 860 February 2022 Yamato Scientific America Inc 925 Wals...