Yamato REV202M Series Скачать руководство пользователя страница 1

 

 

 

 
 
 
 
 

Rotary Evaporator 

 

REV202M series 

 
 

Instruction Manual 

 
 
 
 

First Edition 

 

 

Thank you for choosing REV202M series Rotary 
Evaporator from Yamato Scientific Co., Ltd. 

For proper equipment operation, please read and 

become thoroughly familiar with this instruction manual 
before use. Always keep equipment documentation safe 
and close at hand for convenient future reference. 

Warning

: Read instruction manual warnings and 

cautions carefully and completely before 
proceeding. Read instruction manual thoroughly 
before operation. 

 

 
 
 
 
 
 
 

Yamato Scientific Co. Ltd.

 

 
 

Printed on recycled paper

 

 

 

 

Содержание REV202M Series

Страница 1: ...tion please read and become thoroughly familiar with this instruction manual before use Always keep equipment documentation safe and close at hand for convenient future reference Warning Read instruct...

Страница 2: ......

Страница 3: ...l unit G and vacuum control solenoid valve 15 C When performing vacuum control by Vacuum pump control unit and vacuum control solenoid valve 15 3 PRE OPERATION PROCEDURES 16 Installation Precautions 1...

Страница 4: ...8 Reading Error Codes Control Panel 2 49 Troubleshooting Guide 50 9 SERVICE REPAIR 52 Requests for Repair 52 10 SPECIFICATIONS 53 Specifications 53 List of Consumable Parts 54 11 OPTIONAL ACCESSORIES...

Страница 5: ......

Страница 6: ......

Страница 7: ......

Страница 8: ......

Страница 9: ...R 201 190693...

Страница 10: ...ing flammable chemicals P 4 6 WARNING Fire Electric shock DO NOT disassemble or modify equipment P 5 7 WARNING Fire Choose an appropriate installation site P 16 8 WARNING Injury Install unit on a leve...

Страница 11: ...nnect power cable before daily inspection and maintenance P 46 20 WARNING Fire Electric shock NEVER disassemble or modify unit P 46 Extended storage disposal No Degree of risks Risk description Protec...

Страница 12: ...ing flask Condenser insulation Cooling condenser type A Sample inlet Sample feed stopcock Flask clip Power cable Type of plug differs by models See REV202M Series Product Line Up for details AC adapte...

Страница 13: ...sk Condenser insulation Cooling condenser type B Sample inlet Sample feed stopcock Flask clip Power cable Type of plug differs by models See REV202M Series Product Line Up for details AC adapter DC ja...

Страница 14: ...prox 3 m AC adapter Bath guide Rear cover Tape fastener Used for binding codes and hoses Joint nut Exhaust hose For purging 7 94 14 3 1 m REV202M series Instruction Manual VR102S series Instruction Ma...

Страница 15: ...Fwd Rev AutoR Sync...

Страница 16: ......

Страница 17: ......

Страница 18: ...REV202M series Vacuum pump Vacuum control solenoid valve 1 1 Vacuum control solenoid valve is embedded in the back of main unit...

Страница 19: ...control unit G with pump connector 1 Vacuum control solenoid valve is embedded in the back of main unit 2 Applicable AC pump Yamato Scientific PG201 ULVAC DTC 22 DTC 41 KNF N810 N820 N840 REV202M A RE...

Страница 20: ...ctuate largely where liquid is assumed to splash on unit in excessively humid or dusty locations in direct sunlight or outdoors where there is constant vibration in direct contact with the outside air...

Страница 21: ......

Страница 22: ...is 5 and frequency is 1 Check the line voltage on distribution board and properly evaluate whether to utilize a line being shared by other equipment If unit is not activated by turning ON power take...

Страница 23: ...1 2...

Страница 24: ...3...

Страница 25: ...rts so that they do not get lost Insert the PTFE tube straight into the fitting of the vacuum control solenoid valve then tighten the nut firmly Pull on the PTFE tube to make sure that it does not com...

Страница 26: ...Slide supplied rear cover over the post along its groove Draw power cable and connection cable through the U notch in the bottom of rear cover Exercise caution not to pinch power cable connection cabl...

Страница 27: ...As with the step 1 press in the lock pin to lock the rotary part Screw in joint nut clockwise with the other hand 4 Attach flask removal tool included with glass set Fit flask removal tool over rotary...

Страница 28: ...6...

Страница 29: ...7 8...

Страница 30: ...9 10...

Страница 31: ...olts of condenser bracket with hex wrench See the right figure to rearrange condenser support to the reverse direction Adjust the angle of motor box and control panel according to procedures in Motor...

Страница 32: ...12...

Страница 33: ......

Страница 34: ...ing condenser type B 3 One touch cooling nozzle optional Attach one touch cooling nozzle onto cooling condenser and then insert rigid tube firmly into the condenser Put supplied insert sleeve into rig...

Страница 35: ...14...

Страница 36: ...er connected with a connection cable and can perform the following interlocking operation Run Stop interlocking Starting vacuum control and rotation on either the rotary evaporator or vacuum controlle...

Страница 37: ...Fwd Rev AutoR Sync Fwd Rev AutoR Sync...

Страница 38: ...Fwd Rev AutoR Sync...

Страница 39: ...irection between forward and reverse in accordance with time setting SEC Default setting is F ro P 36 Auto inversion time setting sec Time interval for auto inversion mode can be set Setting range 5 9...

Страница 40: ...tting flashes F ro Forward rotation mode r ro Reverse rotation mode Ato Timed auto inversion mode Turn the Control knob to select rotation mode Press the Control knob to finalize A corresponding lamp...

Страница 41: ...ge auto inversion time setting Turn the Control knob and select SEC RPM display SEC flashes Press the Control knob RPM display Current setting flashes Turn the Control knob to select desired setting S...

Страница 42: ...for two seconds while current rpm is on the screen Unit enters user setting 2 Change the Auto resume setting Turn the Control knob and select Pon RPM display Pon flashes Press the Control knob RPM dis...

Страница 43: ...setting 2 Select the LED brightness level Turn the Control knob and select dSP RPM display dSP flashes Press the Control knob RPM display Current setting flashes Turn the Control knob to select desire...

Страница 44: ...Control knob for two seconds while current rpm is on the screen Unit enters user setting 2 Change connection setting Turn the Control knob and select di RPM display di flashes Press the Control knob R...

Страница 45: ...overflow Start operation with the Run Stop keys on the control panel 1 or control panel 2 Rotate sample feed stopcock slowly so that the yellow mark on the stopcock faces down Sample liquid is drawn i...

Страница 46: ...o the atmosphere 2 Turn jack handle counterclockwise to release the jack Lift slide panel slowly so that evaporation flask comes out of the bath 3 Remove flask clip from evaporation flask 4 Take evapo...

Страница 47: ...Stop Operation 6 Remove condenser fixing band Only for vertical condenser type B 7 Hold cooling condenser by hand and turn condenser nut counterclockwise Remove cooling condenser Turn counterclockwis...

Страница 48: ......

Страница 49: ......

Страница 50: ......

Страница 51: ......

Страница 52: ...ry sensor failure Turn OFF power and restart If unit does not reset contact original dealer of purchase EEPROM failure E15 Error in a storage element EEPROM on the controller board Turn OFF power and...

Страница 53: ...for details...

Страница 54: ...ply Check the piping system Check the piping system Replace relevant parts call for service Replace relevant parts call for service Rotation speed on the control panel 1 is not stable Sample volume is...

Страница 55: ...arts call for service The pressure does not return to atmospheric pressure when the leak key on the control panel 2 is pressed Leak solenoid valve failure Replace relevant parts call for service Contr...

Страница 56: ...ired for all repairs Product Name Model Serial Number Date year month day of Delivery Description of problem in as much detail as possible Repair this equipment for free of charge according to the con...

Страница 57: ...lower part two 10 nozzles Compatible evaporation flask 50 2000ml JIS Use optional reducer to attach small flasks Compatible receiving flask 100 2000 mL External dimensions 2 375W 445H 324D 719W 324D...

Страница 58: ...nts listed below are not covered by the warranty Consumables replacement parts for main unit Sleeve PTFE tube length 700 mm Pressure sensor 1 Part code LT00040261 Part code R102S0002 Part code LT00039...

Страница 59: ...A B E...

Страница 60: ......

Страница 61: ...valve VR attachment bracket Connection cable Exhaust hose For purging Product code 255762 Part code REV02S0010 Product code LT00040442 Part code ORT12S0001 VR102S connection cable and vacuum tube inc...

Страница 62: ...rt code RG02AS0000 Product code 255512 Product code 255742 Product code 281494 Common insulation for cooling condensers GL14 10 mm O D 2 pcs GL14 10 mm O D 2 pcs Gasket for vacuum nozzle 12pcs Options...

Страница 63: ...150 150 mm Height 75 245 mm 200 200 mm Height 75 245 mm 24 40 24 40 24 40 19 38 24 40 15 25 29 38 24 40 29 38 19 38 29 38 15 25 29 38 29 38 29 42 24 40 29 42 19 38 29 42 15 25 29 42 29 42...

Страница 64: ...installed onto Stand Applicable AC pump Yamato Scientific PG201 ULVAC DTC 22 DTC 41 KNF N810 N820 N840 Stand Model ORT10 Product code 255770 Exhaust trap kit Model ORT12 Product code 255773 Solvent re...

Страница 65: ...l2 99 0 1 257 77 3 83 5 111 146 199 1 propanol C3H8O 60 1 0 804 162 6 97 8 27 38 70 2 butanol C4H10O 74 1 0 807 134 4 99 5 24 34 63 water 18 0 0 997 540 0 100 0 32 43 74 Formic acid CH2O2 46 0 1 214 1...

Страница 66: ...orate Ammonium Perchlorate and other perchlorates Potassium Peroxide Sodium Peroxide Barium Peroxide and other inorganic peroxides Potassium Nitrate Sodium Nitrate Ammonium Nitrate and other nitrates...

Страница 67: ...ower supply P 18 P 53 2 Confirmation on operation Explain name and function of each component Start operation Set rotation speed at 100 rpm 2 COMPONENT NAMES AND FUNCTIONS 4 OPERATION PROCEDURES P 8 P...

Страница 68: ...Notice Instruction manual descriptions and specifications are subject to change without notice Yamato Scientific Co Ltd will replace flawed instruction manuals pages missing pages out of order etc up...

Отзывы: