![Yamato Pure Line WL220T Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/yamato/pure-line-wl220t/pure-line-wl220t_instruction-manual_905419035.webp)
32
8.When a trouble occurs
Troubleshooting
Countermeasures when water leak detection error
is displayed
1.Imperfect connection of the water supply port coupler and the ion exchange resin cartridge
coupler
※
When water is leaking from other piping, immediately shut power off and close the main cock
of the tap water and consult your dealer or the general customer service center.
2.When water splashed on the ion exchange resin cartridge during its replacement work.
Countermeasures
(1) Turn the power switch on the right side of the main body to OFF.
(2) Isolate the leaking point. The leak detecting sensors are located at two points below:
・
Inside the door.
・
Inside the left cover of the cock.
(3) Wipe off water remaining in the bottom of the unit and allow it completely dry, remove the
screws that hold the water leak sensor and remove, carefully wipe and allow the electrode
off the main body to completely dry.
(4) When water has been wiped out, be sure to replace the leak detecting sensor to the original
position.
(5) Replace the door or the left side cover.
(6) Turn the power switch on the right side of the main body to ON, press the POWER key on
the operation panel to resume regular operation.
※
Be sure to first close the main cock of raw water before disassembling the piping assembly
for repairing water leak at a pipe or other work.
Leak detecting sensor
Leak detecting sensor