YCO-1125-03-13
PPC-300 & PPC-300D Operation Manual
01 - Function Selection
The PPC-300 series has three user selectable weighing functions: Packing, Checkweighing, and Grad-
ing. The value of this parameter determines which, if any, of the three functions is enabled. For more
information on these functions, please see section IV of this manual.
02 - Number of Grades
The grading function can be set to have 2 to 15 grades. The higher the number of grades, the fewer
the number of different grading setups that can be stored in memory. Please see section IV of this
manual for more information on the grading function.
Setting
002
003
004
005
006
007
008
009
010
011
012
013
014
015
# of grades
2
3
4
5
6
7
8
9
10
11
12
13
14
15
# of setups
66
49
39
33
28
24
22
19
18
16
15
14
13
12
03 - Buzzer
This parameter only applies to the PPC-300WP.
04 - Grade Stability
The grading function can be set to either show a real time display of the calculated grade, or to show
no grade value until a stable weight reading has been acheived. If this parameter is enabled (001) then
the scale will display two dashes in place of the grade value until the weight reading is stable. Then it
will display the appropriate grade.
05 - Auto-off Timer
The PPC-300 series of scales can be set to automatically turn off after a specified time with no activity.
This feature only operates when the scale is using batteries for power.
06 - Automatic Tare
The packing function can be set to automatically tare an initial stable weight, and to automatically clear
the tare when the scale returns to zero.
07 - Flashing Display
This feature is available for the packing, checkweighing and grading functions. For the packing and
checkweigh functions, this feature can be set to operate as specified in the preceeding table. Any set
-
ting between 001 and 004 will cause the display in the grading function to flash when any weight above
or equal to the first, lowest grade weight is detected. Setting 005 is only appicable to the PPC-300WP.
21 - Vibration Compensation
Environments that experience "noise" issues caused by external vibration can set this parameter for a
more stable reading at the cost of a longer response time to calculate a stable weight.
22 - Units at Power On
The units (kg, lb, oz, or lb-oz) that the scale will indicate when it is turned on.
V User Parameters
22
Содержание PPC-300
Страница 2: ......