Содержание IC103CW

Страница 1: ...ad the Operating Instructions and Warranty before operating this unit to assure proper operation After reading these documents be sure to store them securely together with the Warranty in a handy plac...

Страница 2: ...top operation 23 Operating procedures auto start operation 25 Useful functions calibration offset function 27 Useful function setting lock function 28 Useful function power outage compensation functio...

Страница 3: ...hock a bone fracture or intoxication that may leave after effects or require hospitalization or outpatient visits for a long time Note 2 Minor injury means a wound or an electrical shock that does not...

Страница 4: ...Hazard of explosion Caution Cautions Electrical shock Burning Caution for no liquid heating Caution for water leak For water only Poisonous material Prohibitions Prohibition Fire Prohibited Do not di...

Страница 5: ...s bundled When these are used bundled they might overheat causing a fire Take care not to damage electrical power cords Avoid tightly bending pulling with a strong force or twisting to prevent electri...

Страница 6: ...m or more 2 Install the unit on a level surface Install the unit on a level surface If the whole bottom surface of the unit does not contact the surface evenly vibrations or noises may result This mig...

Страница 7: ...not operate the unit at such a place that may subject to splashing liquids Liquid entering the inside may cause an accident a malfunction an electrical shock or a fire 6 Never operate the unit in an...

Страница 8: ...ower cord under a desk or a chair or sandwich between objects to avoid it from being damaged Otherwise a fire or an electrical shock may result Do not place the power cord close to a stove or other he...

Страница 9: ...unit Note that moving the unit over a bump may give an excessive impact to and break the casters Where there is such a bump move the unit by lifting it by at least two people 2 Select an installation...

Страница 10: ...mples with spaces between them Too many samples may prevent proper temperature control To assure proper temperature control put samples with a space at least 30 of the shelf board area Make at least 3...

Страница 11: ...y might corrode with strong acid Note that packing may corrode with acid alkali oil or organic solvents Operation with devices with a larger heat load installed Note that temperature in the chamber ma...

Страница 12: ...10 3 Names and functions of parts Main body Front view of IC103CW 113CW Rear view of IC103CW 113CW Handle Door Caution Plate Power switch SW Power cord Exhaust hole Control panel Observation Window...

Страница 13: ...11...

Страница 14: ...s and functions of parts Main body Front view of IC403C 413C 603C 613C Rear view of IC403C 413C 603C 613C Handle Door Inner door Control panel Caution Plate Power switch SW Power cord Exhaust port Rat...

Страница 15: ...and functions of parts Main body Front view of IC403CW 413CW Rear view of IC403CW 413CW Handle Door Inner door Control panel Caution Plate Power switch SW Power cord Exhaust hole Rating plate Observat...

Страница 16: ...ain body Front view of IC803C 813C Rear view of IC803C 813C Handle Door Inner door Power switch SW Rating sticker Caster wheel with a stopper For front caster wheels only Power cord Exhaust hole Exhau...

Страница 17: ...of the Timer key Key for setting calibration offset temperature the key lock function or the power outage compensation function RUN lamp Illuminates during fixed temperature operation and blinks durin...

Страница 18: ...3 cAL Calibration offset setting Used for inputting a calibration offset temperature See section Using the calibration offset function on page 27 Lock Key lock of settings Key locks settings to preven...

Страница 19: ...fore stop with the keys Pressing the RUN STOP key starts quick auto stop operation and activates the timer in the middle of it to automatically stop it after the set period of time P 21 3 Auto stop op...

Страница 20: ...ature The function can compensate to either plus or minus side for the whole temperature band of the unit This compensation can be set with the SUB MENU keys P 27 2 Setting lock function This function...

Страница 21: ...19 4 Operating procedures Operation mode function setting keys and characters Key operations and characters in the diagram below are used for operation mode and function settings...

Страница 22: ...ing operation Press the RUN STOP key longer Fixed value operation will start and the RUN lamp and the HEATER lamp come on 4 Stopping operation Press the RUN STOP key longer Operation stops the RUN lam...

Страница 23: ...9 hours 59 minutes time can be set in minutes One hundred hours and over are set only in 10 minutes Keep the keys pressed to continuously change set time and you can quickly reach the time you want Pr...

Страница 24: ...om when the set temperature is reached to the time the device shall be stopped When you want to change settings after timer activation press the TIMER key on the current screen to enter the setting mo...

Страница 25: ...s pressed to continuously change set time and you can quickly reach the time you want Press the keys once at a time for fine adjustment MEASURED TEMP HEATER RUN SET TEMP RUN STOP TIMER SUB MENU 2 Star...

Страница 26: ...to the time the device shall be stopped When you want to change settings after timer activation press the TIMER key on the current screen to enter the setting mode where you can change settings Note...

Страница 27: ...rs 59 minutes time can be set in minutes One hundred hours and over are set only in 10 minutes Keep the keys pressed to continuously change set time and you can quickly reach the time you want Press t...

Страница 28: ...me with the keys In either case the set temperature screen will stop blinking after a while and switches to the timer count mode and the change made is determined Note however when you change the set...

Страница 29: ...g to exit the sub menu mode When you want to set the key lock function proceed to character selection process for the key lock function without pressing the TIMER key SUB MENU key long You can set eit...

Страница 30: ...indicate the setting lock function MEASURED TEMP HEATER RUN SET TEMP RUN STOP TIMER SUB MENU Off is displayed on the set temperature screen To lock settings change to on using the key Press the TIMER...

Страница 31: ...ory MEASURED TEMP HEATER RUN SET TEMP RUN STOP TIMER SUB MENU Press the TIMER key SUB MENU key long to enter the sub menu mode Press the TIMER key SUB MENU key several times to select the characters P...

Страница 32: ...ature of the unit will rise degrading the performance and an accident a malfunction or a fire may result 4 Do not allow liquid to spill over the unit Do not allow liquid to spill over the unit Pay spe...

Страница 33: ...utage and resumes operation Turn the power switch off if you do not want to resume operation by automatic recovery 6 About two tier stacking Use the dedicated optional parts to stack units in two tier...

Страница 34: ...e internal chamber Stop operation and turn the power switch to OFF Pull out the power cord off the distribution board and the wall outlet Confirm the temperature in the device and remove shelf boards...

Страница 35: ...spose the unit as a bulky waste Notes about disposition Always pay attention to the preservation of the global environment We highly recommend taking the unit apart as far as possible for separation o...

Страница 36: ...arm buzzer sounds When an abnormality occurs confirm the error code and immediately stop operation Safety device Symptom Possible causes and measures Sensor error appears z Error in the temperature in...

Страница 37: ...supply voltage has declined If ambient temperature fluctuates widely If cooling load for inside the chamber is not too large Displayed temperature differs from the measurement If the calibration offse...

Страница 38: ...ease fill in your dealer date of purchase and other information and store securely Warranty period is one full year from the date of purchase Repair service for free is available according to the cond...

Страница 39: ...offset function Controller Self diagnostic function Temperature sensor error memory error auto overheat prevention measured temperature error Safety device Protection device An over current fuse Oute...

Страница 40: ...T 1 H 2 2 3 4 1 2 3 4 5 6 7 8 9 CO N T CN 1 22 1 1 22 PIO CN 1 TH 1 3 4 SSR 2 TB1 2 4 7 6 1 2 3 2 Symbol Part name Symbol Part name SW Power Switch SSR Solid State Relay F Fuse CONT Control circuit bo...

Страница 41: ...3 2 3 2 1 6 7 4 2 TB1 2 SSR 4 3 1 TH CN 1 PIO 22 1 1 22 CN 1 CO N T 9 8 7 6 5 4 3 2 1 4 3 2 H 2 1 Symbol Part name Symbol Part name SW Power Switch SSR Solid State Relay F Fuse CONT Control circuit bo...

Страница 42: ...F Fuse tube AC250V 15A IC803C 813C YSJ SJK06492 TH K Thermocouple T0304 01 16 3 2 55 2000 DP single YSJ SJA14030 CONT Control board CN40B Y YSC LT00007640 PIO Display board CN40B Y YSC LT00007639 SSR...

Страница 43: ...rate and other perchlorates Potassium peroxide sodium peroxide barium peroxide and other inorganic peroxides Potassium nitrate sodium nitrate ammonium nitrate and other nitrates Sodium chlorite and ot...

Страница 44: ...ications Specification power supply P 6 P 6 P 37 2 Operation start Starts operation Performs fixed temperature ope ration auto stop operation or auto start operation 2 Before operating the unit Instal...

Страница 45: ...s prohibited in this operation instruction Otherwise an unexpected accident may result Notice Descriptions in this operating instruction are subject to change without notice We will replace a manual w...