YCO-201008
DP-6700
Technical Manual
No.
Item
Value
Function
B1(111)
Moving Average Filter 1
000-0008:
Moving Average Tap NO. (Invalid Less Than 2)
B2(112)
Moving Average Filter 2
000-0008:
Moving Average Tap NO. (invalid Less Than 2)
B3(113)
Moving Average Filter 3
000-0016:
Moving Average Tap NO. (invalid Less Than 2)
B4(114)
Moving Average Filter 4
000-0016:
Moving Average Tap NO. (invalid Less Than 2)
C0(120)
Load / Unload Judge
004-255:
C1(121)
Buzzer at Data Transmission
000:
001:
No Sound
Sound
C2(122)
One-Time Addition
000:
001:
Addition any numbers of times
One-Time Addition
How to Set System Parameters
Description
Indication
Display the internal count in test mode, referring to
1.3.1 How
to enter test mode and meanings of panel indications
on
Page
1-5.
When the internal count is shown on the panel, press the
key while holding down the
key; and it switches to dealer
mode.
Going to the next parameter:
Press
key to go to the next parameter.
To change the setup value, enter a new value and go to the
next parameter.
Make sure to go to the next parameter to enable the new value
If you exit before moving to the next parameter, the system
discards the entered value.
Going back to the previous parameter:
To go back to the previous parameter, press the
key while
holding down the
key.
+1 operation for parameter value:
Press the
key to increment the parameter value by 1.
Keeping the
key down for a while automatically increments
the parameter value by 1 continuously
If the value exceeds the setting range, the value returns to 0.
1-12
Chapter 1 Adjustment method
Содержание DP-6700
Страница 2: ...YCO 201008 DP 6700 Technical Manual ...
Страница 28: ...YCO 201008 DP 6700 Technical Manual 1 25 Chapter 1 Adjustment method ...
Страница 29: ...YCO 201008 DP 6700 Technical Manual 1 26 Chapter 1 Adjustment method ...
Страница 30: ...YCO 201008 DP 6700 Technical Manual 1 4 Wiring diagram 1 27 Chapter 1 Adjustment method ...
Страница 32: ...YCO 201008 DP 6700 Technical Manual 1 29 Chapter 1 Adjustment method ...
Страница 33: ...YCO 201008 DP 6700 Technical Manual 1 30 Chapter 1 Adjustment method ...
Страница 38: ...YCO 201008 DP 6700 Technical Manual Chapter 3 How to disassemble 3 1 ...
Страница 39: ...YCO 201008 DP 6700 Technical Manual Chapter 3 How to disassemble 3 2 ...
Страница 40: ...YCO 201008 DP 6700 Technical Manual Chapter 3 How to disassemble 3 3 ...
Страница 41: ...YCO 201008 DP 6700 Technical Manual Chapter 3 How to disassemble 3 4 ...
Страница 54: ...YCO 201008 DP 6700 Technical Manual ...