2 - 14
Electrical Wiring (6)
Pulse output wiring
The pulse output is an open collector output.
Pay close attention to voltage and polarity when wiring.
Figure 2-12 Wiring diagram for pulse output
Protective diode
200mA max.
Load
this is impossible
Note:
• Miswiring of polarity may cause damage to the equipment.
Recheck the wiring position carefully.
Use an external power supply with voltage and capacity that satisfy
the specifications.
External
power supply
30V max.