6D03F1X
74
Self-diagnosis
9
Diagnosing the electronic control
system
1.
Connect the special service tool to the
outboard motor as shown.
NOTE:
When performing this diagnosis, all of the
electrical wires must be properly connected.
2.
Start the engine and let it idle.
3.
Check the flash pattern of the diagnostic
flash indicator to determine if there are
any malfunctions.
• Normal condition
(no defective part or irregular process-
ing is found)
• Single flash is given every 4.95 sec-
onds.
a
: Light on, 0.33 second
b
: Light off, 4.95 seconds
• Trouble code indication
Example: The illustration indicates
code number 23.
a
: Light on, 0.33 second
b
: Light off, 4.95 seconds
c
: Light off, 0.33 second
d
: Light off, 1.65 seconds
Diagnostic flash indicator B:
90890-06865
Electrical components / Self-diagnosis
1
2
3
4
5
6
7
8
9
Содержание Z300A
Страница 1: ...Z300A LZ300A SUPPLEMENTARY SERVICE MANUAL 292211 6D0 28197 3F 1X...
Страница 85: ...6D03F1X 78 Index MEMO...
Страница 87: ......