3-41
Measure the open-circuit
voltage prior to charging.
Connect a charger and
AMP meter to the battery
and start charging.
NOTE:
Voltage should be measured 30 min-
utes after the machine is stopped.
Make sure the current is
higher than the standard
charging current written on
the battery.
Charge the battery until the battery’s
charging voltage is 15 V.
This type of battery charger cannot
charge the MF battery. A variable volt-
age charger is recommended.
Measure the battery open-circuit
voltage after having left the battery
unused for more than 30 minutes.
12.8 V or more --- Charging is com-
plete.
12.7 V or less --- Recharging is re-
quired.
Under 12.0 V --- Replace the battery.
NOTE:
Set the charging time at 20 hours (maxi-
mum).
YES
NO
Charging method using a constant-current type charger
This type of battery charger cannot charge the MF battery.
Volt meter
Charger
AMP meter
BATTERY INSPECTION
INSP
ADJ
Charging method using a constant-voltage type charger
Содержание XVS6501997
Страница 1: ......
Страница 2: ......
Страница 8: ......
Страница 10: ...GEN INFO ...
Страница 18: ...GEN INFO ...
Страница 20: ...SPEC ...
Страница 44: ...2 24 LUBRICATION DIAGRAMS SPEC 1 Crankshaft 2 Oil filter 3 Oil pump ...
Страница 45: ...2 25 4 Drive axle 5 Main axle 1 Camshaft 2 Rocker arm 3 Starter idle gear LUBRICATION DIAGRAMS SPEC ...
Страница 102: ...INSP ADJ ...
Страница 148: ...4 44 SHIFT SHAFT ENG NOTE 2 Install Shift lever Insert the shift arm 1 between the pins on the shift cam segment ...
Страница 188: ...CARB ...
Страница 198: ...CARB ...
Страница 266: ...CHAS ...
Страница 268: ...ELEC SELF DIAGNOSIS 7 49 TROUBLESHOOTING 7 50 ...
Страница 298: ...E 7 30 SIGNAL SYSTEM ELEC EB806000 SIGNAL SYSTEM CIRCUIT DIAGRAM ...
Страница 320: ...TRBL SHTG ...
Страница 326: ...TRBL SHTG ...