background image

 

2   

 

XP7000/XP5000/XP3500/XP2500/XP1000 Owner’s Manual

 

The above warning is located on the top of the unit.

 

Explanation of Graphical Symbols

 

The lightning flash with arrowhead symbol 
within an equilateral triangle is intended to alert 
the user to the presence of uninsulated 
“dangerous voltage” within the product’s 
enclosure that may be of sufficient magnitude to 
constitute a risk of electric shock to persons.

The exclamation point within an equilateral 
triangle is intended to alert the user to the 
presence of important operating and 
maintenance (servicing) instructions in the 
literature accompanying the product.

 

IMPORTANT SAFETY INSTRUCTIONS

 

1

Read these instructions.

2

Keep these instructions.

3

Heed all warnings.

4

Follow all instructions.

5

Do not use this apparatus near water.

6

Clean only with dry cloth.

7

Do not block any ventilation openings. Install in 
accordance with the manufacturer’s instructions.

8

Do not install near any heat sources such as radiators, 
heat registers, stoves, or other apparatus (including 
amplifiers) that produce heat.

9

Do not defeat the safety purpose of the polarized or 
grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding type plug 
has two blades and a third grounding prong. The wide 
blade or the third prong are provided for your safety. If 
the provided plug does not fit into your outlet, consult 
an electrician for replacement of the obsolete outlet.

10

Protect the power cord from being walked on or pinched 
particularly at plugs, convenience receptacles, and the 
point where they exit from the apparatus.

11

Only use attachments/accessories specified by the 
manufacturer.

12

Use only with the cart, stand, 
tripod, bracket, or table specified 
by the manufacturer, or sold with 
the apparatus. When a cart is 
used, use caution when moving 
the cart/apparatus combination 
to avoid injury from tip-over.

13

Unplug this apparatus during 
lightning storms or when unused for long periods of 
time.

14

Refer all servicing to qualified service personnel. 
Servicing is required when the apparatus has been 
damaged in any way, such as power-supply cord or plug 
is damaged, liquid has been spilled or objects have 
fallen into the apparatus, the apparatus has been 
exposed to rain or moisture, does not operate normally, 
or has been dropped.

 

(98-6500)

CAUTION: TO REDUCE THE RISK OF 

ELECTRIC SHOCK, DO NOT REMOVE 

COVER (OR BACK). NO USER-SERVICEABLE 

PARTS INSIDE. REFER SERVICING TO 

QUALIFIED SERVICE PERSONNEL.

C A U T I O N

RISK OF ELECTRIC SHOCK

DO NOT OPEN

 

WARNING

 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.

 

FCC INFORMATION (U.S.A.)

 

1. IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT!

 

This product, when installed as indicated in the instructions contained in this manual, meets FCC requirements. Modifications not 
expressly approved by Yamaha may void your authority, granted by the FCC, to use the product.

 

2. IMPORTANT:

 

 When connecting this product to accessories and/or another product use only high quality shielded cables. Cable/s 

supplied with this product MUST be used. Follow all installation instructions. Failure to follow instructions could void your FCC authori-
zation to use this product in the USA.

 

* This applies only to products (XP7000, XP5000) distributed by YAMAHA CORPORATION OF AMERICA.

(oscillator)

Содержание XP1000

Страница 1: ...POWER AMPLIFIER OWNER S MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE INSTRUCCIONES ES FR DE EN English Deutsch Français Español ...

Страница 2: ...point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long pe...

Страница 3: ...oving the device remove all connected cables When setting up the product make sure that the AC outlet you are using is easily accessible If some trouble or malfunction occurs immediately turn off the power switch and disconnect the plug from the outlet Even when the power switch is turned off electricity is still flowing to the product at the minimum level When you are not using the product for a ...

Страница 4: ...ponents Illustrations in this manual are for explanatory purposes only and may not match the actual appearance of the product during operation Company names and product names used in this Owner s Manual are trademarks or registered trademarks of their respective owners Handling caution Yamaha cannot be held responsible for damage caused by improper use or modifications to the device or data that i...

Страница 5: ...step Volume control are provided for each channel A PROTECTION indicator that shows the state of various protection systems power on off detection output protection DC detection a TEMP indicator that indicates heat sink overheating and a POWER STANDBY indicator that indicates the power status Variable speed low noise fans ensure high reliability The XP7000 enables parallel connection of multiple h...

Страница 6: ...turn off the amplifier and allow it time to cool down See the Pre cautions section of this Owner s Manual for ways to prevent the amplifier from overheating 4 CLIP indicator Lights up red when the output signal distortion on the corresponding channel rises above 1 indicating that clipping has occurred bacause the signal level is too high 5 SIGNAL indicator Lights up green when the corresponding ch...

Страница 7: ...witch STEREO mode In STEREO mode channels A and B are completely independent PARALLEL mode In PARALLEL mode the channel A input signal is sent both to the channel A power amp and the channel B power amp In this case loads are automatically connected between the A and B input terminals BRIDGED mode In BRIDGED mode channels A and B operate simul taneously functioning as a single mono amplifier 6 MON...

Страница 8: ...e volume controls on the front panel A and B let you control the volume of each channel independently 5 way binding post Speakon connector Parallel Mode Set the Mode switch to PARALLEL to use the unit as a two channnel mono amplifier The volume controls on the front panel A and B let you control the volume of each channel independently 5 way binding post Speakon connector Note In this case the loa...

Страница 9: ...the unit as a high power mono amplifier The volume control A on the front panel A lets you control the volume 5 way binding post Speakon connector Note In this case the loads for A and B are directly connected in the amplifier Make sure not to input any signal to the B terminal Minimum speaker impedance 8Ω Minimum speaker impedance 8Ω ...

Страница 10: ...akers at 15 W for 315 W The total is 625 W per channel Be sure to use speakers that support the XP7000 s line out voltage of 70 V The XP3500 enables you to connect in bridge fashion multiple high impedance speakers that support 100V line output You can connect speakers with a total rated input of up to 625 W Be sure to use speakers that support the XP3500 s line out voltage of 100 V 1 21 1 31 1 31...

Страница 11: ...aker terminals Tighten the terminals to securely clamp the wires Refer to page 8 for speaker polarities Be sure that the bare wire ends do not jut out from the terminals and touch the chassis 4 Reattach the protective cover over the speaker termi nals Speakon connector 1 Turn off the POWER switch 2 Insert the Neutrik NL4FC plugs into the Speakon con nector on the rear of the amplifier and turn clo...

Страница 12: ...low around the amplifier The TEMP indicator lights up to indicate tem perature warning PROTECTION indica tor lights The heat sink temperature has exceeded 90 C 194 F Check the amplifier ventilation conditions and take appropriate measures to improve the airflow around the amplifier The thermal protection circuit operates to protect the power transistors Indicator s Possible Cause Remedy Protection...

Страница 13: ...4 Ω STEREO 590 W 590 W 590 W 590 W 590 W 590 W 8 Ω BRIDGED 1180 W 1180 W 1180 W 20 20 kHz THD N 0 1 8 Ω STEREO 350 W 350 W 350 W 350 W 350 W 350 W 4 Ω STEREO 450 W 450 W 435 W 435 W 450 W 450 W 8 Ω BRIDGED 900 W 870 W 900 W 100 V BRIDGED RL 16 Ω 625 W 625 W 625 W 1 kHz 20mS nonclip 2 Ω STEREO 1000 W 1000 W 925 W 925 W 1000 W 1000 W 4 Ω BRIDGED 2000 W 1850 W 2000 W SN Ratio 20Hz 20kHz DIN AUDIO MIN...

Страница 14: ... dBu 26 dB position 13 7 dBu 120V 240V 13 6 dBu 230V 12 2 dBu 10 7 dBu 9 2 dBu 5 2 dBu 32 dB position 7 7 dBu 120V 240V 7 6 dBu 230V 6 2 dBu 4 7 dBu 3 2 dBu 0 8 dBu Maximum Input Voltage MIN 22 dBu Input Impedance TYP 20 kΩ balanced 10 kΩ unbalanced Controls Front Panel POWER switch push on push off attenuator 31 position x 2 Rear Panel MODE switch STEREO BRIDGED PARALLEL x 1 HPF switch 20 Hz 55 H...

Страница 15: ...to GND 4 REMOTE CONTROL NC 5 NC 6 MUTE CH B MUTE On Control Connect the pin to GND max 1mA flows MUTE Off Control Open the pin 5V applied 7 MUTE CH A 8 MONITOR NC 9 NC 10 PROTECTION MUTE STATUS CH B Protection Mute On 5 VDC Zo 270 Ω Protection Mute Off 0 VDC Zo High 11 PROTECTION MUTE STATUS CH A 12 NC 13 NC 14 OUTPUT LEVEL CH B XP7000 XP5000 XP3500 XP2500 XP1000 4dBu 27 2 dB of Speaker Output Lev...

Страница 16: ...ECTION SIGNAL CLIP LIMIT RE GR GR RE RE BSIG TEMPERATURE SENSOR TEMPERATURE SENSOR PROTECTION CIRCUIT FAN CONTROL CIRCUIT POWER ON DETECT CIRCUIT LIMITER LIMITER PA 5V 5 B 15 15 B 24 24 15V 15V 15V U A destination J H destination GAIN HA BA BA CH A ATT CH B ATT MODE LED DRIVE CIRCUIT PO SBY POWER STANDBY POWER SW LINE FILTER RELAY DRIVE CIRCUIT RELAY Thermal cutoff SUB TRANS SWITCHING MAIN TRANS D...

Страница 17: ...E CIRCUIT CH B TEMP PROTECTION SIGNAL CLIP LIMIT RE GR GR RE RE SP RELAY BSIG TEMPERATURE SENSOR LED DRIVE CIRCUIT FAN CONTROL CIRCUIT PROTECTION CIRCUIT LIMITER LIMITER PA 24 24 B B 15 15 15V Thermal cutoff Thermal cutoff RELAY 1 RELAY 2 Thermal protector 15V MAIN TRANS SUB TRANS FAN GAIN HA BA BA CH A ATT CH B ATT MODE PO SBY RELAY LED DRIVE CIRCUIT POWER STANDBY POWER SW J destination only Exce...

Страница 18: ...0 240V In Out Dissipated Btu h kcal h standby 0 08 0 04 5 0 5 17 4 idle 1 0 0 5 35 0 35 119 30 1 8 power 8Ω ch 4 0 2 2 277 131 146 499 126 4Ω ch 6 2 3 4 436 188 249 848 214 1 3 power 8Ω ch 9 3 5 1 673 350 323 1100 278 4Ω ch 14 7 8 1 1057 500 557 1900 479 Line Current A Power W Thermal Dissipation 100 120V 230 240V In Out Dissipated Btu h kcal h standby 0 08 0 04 5 0 5 17 4 idle 1 0 0 5 30 0 30 102...

Страница 19: ...XP7000 XP5000 XP3500 XP2500 XP1000 Owner s Manual 19 Memo ...

Страница 20: ...20 XP7000 XP5000 XP3500 XP2500 XP1000 Owner s Manual Memo ...

Страница 21: ......

Страница 22: ... S G Pro Audio Division 2005 Yamaha Corporation 305POAPx x 01E0 Printed in Vietnam WF37200 Yamaha Pro Audio global web site http www yamahaproaudio com Yamaha Manual Library http www yamaha co jp manual ...

Отзывы: