3
Data setting
3-2
2. Point data
The point data includes items such as the "RUN type", "Position", and "Speed", etc.
Point data item list
n
P1 to P255
Item
Description
1
RUN type
Specifies the positioning operation pattern.
2
Position
Specifies the positioning target position or movement amount.
3
Speed
Specifies the positioning speed.
4
Accel.
Specifies the positioning acceleration.
5
Decel.
Specifies the positioning deceleration
(as a percentage of the acceleration).
6
Push
Specifies the electrical current limit value for "Push" operations.
7
Zone (-)
Specifies the "personal zone" output range.
8
Zone (+)
9
Near width
Specifies the "near width" zone
(distance tolerance relative to target position).
10
Jump
Specifies the next movement destination, or the next merge operation merge destination
point No. following positioning completion.
11
Flag
Specifies other information related to the positioning operation.
12
Timer
Specifies the waiting time (delay) after positioning completion.
"Standard setting" and "Custom setting"
n
There are 2 setting types for point data ("Standard setting" or "Custom setting"). Select the desired setting type according
to the application.
The maximum number of setting points for both setting types is 255 points (P1 to P255).
Setting Type
Description
Standard setting
Optimum positioning is provided simply by specifying the payload. This setting type is well-
suited to assembly and transport applications.
Custom setting
Allows changing the speed and acceleration in SI units so the desired positioning
operation can be set.
This setting type is suited for machining and inspection systems.
n
"Standard setting" and "Custom setting" selection
Specify the "Point Type" setting as "Standard setting" or "Custom setting" during initial processing performed by the support
software (TS-Manager).
c
CAutIoN
• The "Point Type" ("Standard setting" or "Custom setting") can be selected only when creating new robot data
with the support software (tS-Manager).
• Changing the "Point Type" setting clears all point data which has been in use.
Be sure to specify the "point type" setting before editing the point data.
Содержание TS-S
Страница 2: ......
Страница 12: ......
Страница 14: ......
Страница 28: ......
Страница 70: ......
Страница 72: ......
Страница 92: ......
Страница 164: ......
Страница 172: ......
Страница 174: ......
Страница 230: ......
Страница 232: ......
Страница 254: ......
Страница 274: ......
Страница 276: ......
Страница 285: ......