5.9 Continuous query
This function outputs operation information such as the current position and speed, etc., in a continuous
manner.
Input
Command Option
Command
WIN3
WIN2
WIN1
WIN0
-
-
Type
8100h
Output
Command Response
Status
WOUT3
WOUT2
WOUT1
WOUT0
Data
-
0200h
c
CAutIoN
output occurs as 2-word, little Endian data.
When the gateway function is set enabled, the continuous query cannot be used.
Command type and response data
n
Command (WIN0)
Type (WIN1)
Data (WOUT2, WOUT3)
Units
8100h
0000h
Current position
Other than TS-P : 0.01mm
TS-P
: 0.001mm
0001h
Current speed
0.01mm/s
0002h
Electrical current
%
0009h
Voltage
0.1V
000Ah
Temperature
˚C
000Dh
Current point No.
-
000Eh
Load rate
%
0100h
Bit status
-
Timing chart
n
Status (WOUT0)
0000h
0000h
0200h
Command option
(WIN1)
0000h 0000h
0000h
Command (WIN0)
0000h
8100h
0000h
Command response
(WOUT2, WOUT3)
00000000h
Data updating
Stop
Td
Timing chart
For a current position continuous query
23540-M0-00
* Data updates occur every 5ms.
* Data updates continue until a 0x0000 (status clear) command is specified.
* Data updates output continuously until the status becomes the command ready status by executing the status clear (no
execution) (WIN0=0000h).
To put in the command ready status without stopping the data update, execute the status clear (continuous query
continuation) (WIN0=8000h).
n
NOTE
This function is available from CC-Link controller's software version Ver. 1.08.118 onwards and DeviceNet and
EtherNet/IP controller's software version Ver. 1.10.121 onwards.
Содержание TS-S
Страница 2: ......
Страница 12: ......
Страница 14: ......
Страница 28: ......
Страница 70: ......
Страница 72: ......
Страница 92: ......
Страница 164: ......
Страница 172: ......
Страница 174: ......
Страница 230: ......
Страница 232: ......
Страница 254: ......
Страница 274: ......
Страница 276: ......
Страница 285: ......