51
SPX2000
■
ERROR MESSAGE LIST
Error message
Message content/Action
Low Battery!
The internal backup battery has run down.
If the battery goes dead, the internal data will be lost. Press any button to cancel the error message.
Then immediately use the “BULK OUT (ALL)” function to save the internal data on your computer
or on external device. After you have saved the data, replace the backup battery (lithium battery).
MIDI Framing Error!
A MIDI framing error has occurred.
Press any button to cancel the error message. Then try transmitting the MIDI data once again.
MIDI OUT is NOT Selected!
Since the “MIDI OUT/THRU” connector is set to “THRU,” MIDI messages cannot be transmitted.
If you want to transmit MIDI messages, use the “MIDI OUT SETUP” function to set the [MIDI
OUT/THRU] connector to “OUT.”
MIDI Overrun Error!
A MIDI overrun error has occurred.
Press any button to cancel the error message. Then try transmitting the MIDI data once again.
MIDI Parity Error!
A MIDI parity error has occurred.
Press any button to cancel the error message. Then try transmitting the MIDI data once again.
MIDI Rx Buffer Full!
The MIDI reception buffer is full.
Press any button to cancel the error message. Then try transmitting the MIDI data once again. If
the error occurs again, try increasing the spacing between the MIDI data that is transmitted, or take
other measures to prevent a large amount of MIDI data from being transmitted at once.
NO FINE PARAMETER
This effect has no Fine parameters.
Effects of the CLASSIC bank have no Fine parameters; this message will appear if you press the
[FINE PARAM] button for an effect of the CLASSIC bank. Use the [PARAMETER] button to
select Basic parameters.
Not Available in Compare Mode!
You pressed an unavailable button while comparing the effect (while the [COMPARE] LED is
blinking). Press the [COMPARE] button to defeat Compare before you perform the desired
operation.
Operation Locked!
The button etc. you attempted to operate has been disabled by the “OPERATION LOCK” function.
Defeat the restriction as necessary.
PORT GENERAL is Selected OFF!
MIDI messages cannot be transmitted because the MIDI port (GENERAL) is turned OFF.
If you want to transmit MIDI messages, set the “MIDI PORT GENERAL” setting to the port that
you want to use for MIDI message transmission and reception.
U## Program is Empty!
There is no effect to recall.
Please re-select an effect to recall.
The clock of the received digital input signal differs from the SPX2000’s operating clock.
You selected the PRESET bank or CLASSIC bank as the effect store-destination.
Since the PRESET bank and CLASSIC bank are read-only, you cannot change store to these
effects, or change the effect name, protect setting, or display background color. Press any button to
cancel the error message. Then select a store-destination from the USER bank.
The effect store-destination is protected.
Press any button to cancel the error message. Then defeat the protect setting as desired.
The USB reception buffer is full.
Press any button to cancel the error message. Then try transmitting the MIDI data once again. If
the error occurs again, try increasing the spacing between the MIDI data that is transmitted, or take
other measures to prevent a large amount of MIDI data from being transmitted at once.
WRONG WORD CLOCK!
The word clock signal from an external device has been interrupted, or is a frequency to which the
SPX2000 cannot synchronize. Check whether there are any problems with the connection from
the device supplying the word clock, and verify that the word clock settings are correct.