For Service Engineer
Service Information
SI1705004E-00=SIGMA-G5SII Service Manual
82/273
(5) When the Maintenance Mode Change Mode is started, perform the following operation.
While " " is indicated, when the selection in the area of " " in the
lower right is canceled, a square is displayed in the center of the window.
When the item in the area of " " in the lower middle is selected within 5 seconds
after the square is displayed, the Maintenance Mode is changed and the [Debug]
button is displayed on the lower left of the window.
Note:
(a) During the period from the Maintenance Mode Change Mode start to the Maintenance Mode
Change completion, or the Maintenance Mode Change Mode start to the Maintenance Mode
Change Mode stop, the mouse cursor is hidden.
(b) When a certain operation has not been completed within the specified time period, an incorrect
operation is performed or the window is transferred to another one in the Maintenance Mode
Change Mode, the Maintenance Mode Change Mode is stopped and the procedure from Step
(2) should be repeated.
2.9.1. Main Additional Items in the "Debug Mode"
Unit Adjustment : Linear measure correction value, feeder base, cutter, conveyor/driver
management, (Tray) manual operation, nozzle change manual
operation and component check for multi-functional head
Properties in
: Network Setting
System Setting
Debug
: Inter-CPU communication, option switch, operation changer, system
log, event log and Input/Output Machine Signal
2.9.2. Escape from Debug Mode
Make sure to escape from the Debug mode when the required operation is completed.
The escape from Debug mode is available using either of the following three procedures.
Perform the following operation in the window.
Return → Setup → Operator 1 → Return → Setup (or Maint.) → Supervisor
Shut down the machine.
Perform the same procedure which was done to set the machine to Debug Mode