For Service Engineer
Service Information
SI1705004E-00=SIGMA-G5SII Service Manual
235/273
(3)
Remove the setscrews in the four locations in the touch panel support section and
remove the touch panel only.
6.3.2. Touch Panel Attachment Procedure
For the touch panel attachment procedure, use the reverse procedure for the removal.
(Refer to "6.3.1 Touch Panel Removel Procedue")
6.3.3. Touch Panel Adjustment Procedure
(1) Open the Debug Mode window.
Refer to "2.9 Change Procedure to Debug Mode" in Chapter 2, for Debug Mode
window display procedure.
(2) After displaying the Debug Mode window, touch the location around the center of
the lower section of the panel. (Refer to Fig. F5). After tap, three icons are displayed
on the left hand side. Select the Windows icon.
Remove the screws in specified four locations.
Fig.F4
Fig.F5
2. Select the Windows icon.
1. Tap the specified section