For Service Engineer
Service Information
SI1705004E-00=SIGMA-G5SII Service Manual
189/273
4.19.3. Disengaged Latch Sensor Amplifier Adjustment
(1)
For the Disengaged Latch Detection, position it on the feeder base and set it so that the
light is received.
(2)
First, set the power tuning setting value to
"
2000
"
. At that time, do not set up the feeder.
*
Refer to the following figure for the amplifier adjusting procedure.
Set the control output to
"
Back Lighting Type
"
.
Press the output switch button and turn ON the L/D indicator lamp
"
L
"
.
Percent Tuning Mode Setting
Press the mode change button for 3 seconds or more and set the function.
Function Selection
⇒
Press the +/- button to set it to the following value and determine the value using the
mode change button.
Detection Function
⇒
Press the +/- button to set it to the following value and determine the value using the
mode change button.
DPC Function
⇒
Press the +/- button to set it to the following value and determine the value using the
mode change button.
Timer Function
⇒
Press the +/- button to set it to the following value and determine the value using the
mode change button.