PREPARATIONS
➤
Optimizing the speaker settings automatically (YPAO)
En
41
5
Disconnect the YPAO microphone from the unit.
This completes optimization of the speaker settings.
Measuring at multiple listening positions
(multi measure)
When “Multi Position” is set to “Yes”, follow the procedure below for
measurement. It takes about 10 minutes to measure 8 listening
positions.
• If any error message (such as E-1) or warning message (such as W-1) appears,
see “Error messages” (p.44) or “Warning messages” (p.45).
1
To start the measurement, use the cursor keys to
select “Measure” and press ENTER.
The measurement will start in 10 seconds. Press ENTER
again to start the measurement immediately.
• To cancel the measurement temporarily, press RETURN.
The following screen appears on the TV when the
measurement at the first position finishes.
2
Move the YPAO microphone to the next listening
position and press ENTER.
Repeat step 2 until measurements at all listening positions
(up to 8) have been taken.
Caution
• The YPAO microphone is sensitive to heat, so should not be placed anywhere
where it could be exposed to direct sunlight or high temperatures (such as on
top of AV equipment).
1 2 3 4 5 6 7 8 9 10
ENTER
RETURN
Cursor keys