Owner’s Manual
9
Controls and F
u
nctions
Controls and Functions
Front Panel
q
SLOT 1–4 [LOCK] indicators
These indicate the word clock status of slots 1–4. The
indicator is lit green if operation is normal.
NOTE
• If the SLOT1–4 [LOCK] indicators and the SLOT1–4 [SRC]
indicators and all WORD CLOCK indicators sim
u
ltaneo
u
sly
flash red at start
u
p, o
v
erc
u
rrent has occ
u
rred in a Mini-
YGDAI card, or a malf
u
nctioning Mini-YGDAI card is
installed. T
u
rn off the po
w
er and remo
v
e the card that is
ca
u
sing the pro
b
lem.
• If the SLOT1–4 [LOCK] indicators and the SLOT1–4 [SRC]
indicators alternately flash red at start
u
p, the hard
w
are
settings of the RSio64-D need to
b
e
u
pdated (page 20).
• If the SLOT1–4 [LOCK] indicators seq
u
entially light green in
the order of 1–4 at start
u
p, the clocks of the slots are
synchronizing. This may take se
v
eral tens of seconds.
w
SLOT 1–4 [SRC] indicators
These indicate the SRC (Sampling Rate Converter)
status of slots 1–4.
NOTE
The SRC clock sent to a Mini-YGDAI card installed in a slot
is selected
b
y the SRC WCLK DIP s
w
e
SLOT 1–4 [SRC] keys
For each slot, these turn SRC on/off for the slot’s input
as well as output.
O
N
1 2 3 4 5 6 7 8
O
N
1 2 3 4
o !0
r
!3
t
y
q
!3
w e
u
i
!1 !2
Unlit
No card is installed in the slot, or an
u
ns
u
p-
ported card is installed.
Green (lit)
LOCK
This indicates that a clock synchronized
w
ith
the clock so
u
rce selected
b
y the WORD
CLOCK select key is
b
eing inp
u
t from the card.
If an external de
v
ice is connected to the corre-
sponding slot, inp
u
t/o
u
tp
u
t is occ
u
rring cor-
rectly
b
et
w
een that de
v
ice and the RSio64-D.
If the sampling freq
u
ency is close, this stat
u
s
is sho
w
n in some cases e
v
en if not synchro-
nized.
Green
(flashing)
SYNC
ERROR
A
v
alid clock is
b
eing inp
u
t from the card,
bu
t is
not synchronized
w
ith the clock so
u
rce
selected
b
y the WORD CLOCK select key. If
an external de
v
ice is connected to the corre-
sponding slot, inp
u
t/o
u
tp
u
t is not occ
u
rring
correctly
b
et
w
een that de
v
ice and the RSio64-
D. Inp
u
t/o
u
tp
u
t
w
ill occ
u
r correctly if SRC is
t
u
rned ON.
Red (lit)
UNLOCK
A
v
alid clock is not
b
eing inp
u
t from the card. If
an external de
v
ice is connected to the corre-
sponding slot, inp
u
t/o
u
tp
u
t cannot occ
u
r cor-
rectly
b
et
w
een that de
v
ice and the RSio64-D.
Red
(flashing)
WRONG
WORD
CLOCK
The freq
u
ency of the clock so
u
rce selected
b
y
the WORD CLOCK select key is o
u
tside the
range of operating freq
u
encies of the card
installed in the slot. Either set the freq
u
ency of
the clock so
u
rce to
b
e
w
ithin the operating
range of the card, or t
u
rn SRC on. In the case
of an analog card, t
u
rning SRC on makes the
card operate at the RSio64-D’s internal fre-
q
u
ency of 4
8
kHz.
Unlit
SRC is off.
Green (lit)
SRC is on, and the clock selected
b
y the SRC
WCLK DIP s
w
itch is
b
eing inp
u
t correctly.
Red (lit)
SRC is on,
bu
t an appropriate clock is not
b
eing inp
u
t. It may
b
e that the clock selected
b
y the SRC WCLK DIP s
w
itch is not
b
eing
inp
u
t, or is o
u
tside the operating range. Either
t
u
rn SRC off, or change the setting of the DIP
s
w
itch.
Содержание RSio64-D
Страница 25: ...Owner s Manual 167 Dimensions Dimensions ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 88 365 480 430 360 Unit mm ...
Страница 27: ...Owner s Manual 169 ...
Страница 29: ...MEMO ...