5-2
5-3
Chapter
5
PARALLEL I/O INTERF
ACE
1.2 Connector I/O signals
■
I/O signals when ID = 1
PIN
I/O
Signal
Remarks
1
DI01
Servo ON
Dedicated input
2
DI10
Sequence program control
Dedicated input
3
DI03
Step run
Dedicated input
4
CHK1
Check input 1
Shorted to CHK2
5
DI05
I/O command run
Dedicated input
6
DI06
Spare
Do not use.
7
DI07
Spare
Do not use.
8
DI20
General-purpose input 20
9
DI21
General-purpose input 21
10
DI22
General-purpose input 22
11
DI23
General-purpose input 23
12
DI24
General-purpose input 24
13
DI25
General-purpose input 25
14
DI26
General-purpose input 26
15
DI27
General-purpose input 27
16
DO00
EMG monitor (emergency stop monitor)
Dedicated output
17
DO01
CPU OK
Dedicated output
18
DO10
AUTO mode
Dedicated output
19
DO11
Return-to-origin complete
Dedicated output
20
DO12
Sequence program in progress
Dedicated output
21
DO13
Auto operation in progress
Dedicated output
22
DO14
Program reset output
Dedicated output
CHK1 and CHK2
must be shorted.
(See note below.)
23
DO15
Battery alarm output
Dedicated output
24
DO16
END
Dedicated output
25
DO17
BUSY
Dedicated output
26
DI12
Auto operation start
Dedicated input
27
DI13
AUTO mode switching
Dedicated input
28
DI14
Return-to-origin
Dedicated input
29
DI15
Program reset input
Dedicated input
30
DI16
MANUAL mode
Dedicated input
31
DI17
ABS (absolute) reset
Dedicated input
32
DI30
General-purpose input 30
33
DI31
General-purpose input 31
34
DI32
General-purpose input 32
35
DI33
General-purpose input 33
36
DI34
General-purpose input 34
37
DI35
General-purpose input 35
38
DI36
General-purpose input 36
39
DI37
General-purpose input 37
40
CHK2
Check input 2
Shorted to CHK1
41
DO02
Servo-on state
Dedicated output
42
DO03
Alarm
Dedicated output
43
DO20
General-purpose output 20
44
DO21
General-purpose output 21
45
DO22
General-purpose output 22
46
DO23
General-purpose output 23
47
DO24
General-purpose output 24
48
DO25
General-purpose output 25
49
DO26
General-purpose output 26
50
DO27
General-purpose output 27
n
NOTE
• CHK1 and CHK2 inputs are used to check the connector connection.
Always short them together when the ID is set to 1.
• When a serial IO option is installed in the controller and the serial IO is
enabled, the dedicated inputs of the DIO option are disabled. (Only the
dedicated inputs of the serial IO are enabled.)
c
CAUTION
• DI06 and DI07 cannot be used.
• DO15 outputs a "low voltage alarm" when the absolute backup battery or
system backup battery voltage drops.
• Area check outputs can be assigned to DO20 to DO27.
1. Standard I/O interface overview
Содержание RCX222
Страница 1: ...RCX222 EUR2153130 E99 Ver 1 30 Userʼs Manual YAMAHA 2 AXIS ROBOT CONTROLLER ...
Страница 2: ......
Страница 14: ......
Страница 43: ......
Страница 46: ......
Страница 50: ...4 MEMO ...
Страница 51: ...Chapter 1 USING THE ROBOT SAFELY Contents 1 Operating environment 1 1 ...
Страница 52: ......
Страница 56: ......
Страница 98: ......
Страница 388: ......
Страница 412: ...5 24 MEMO ...
Страница 414: ......
Страница 430: ......
Страница 442: ......
Страница 450: ...8 8 MEMO ...
Страница 452: ......
Страница 523: ......