Graphic EQ, Parametric EQ, effects, and Premium Rack
Reference Manual
124
4
RACK LINK button
Press this button to open the RACK LINK window, in which you can link adjacent GEQ
units.
In the case of a 31bandGEQ, the GEQ units in adjacent odd-numbered/even-numbered
racks will be linked. In the case of a Flex15GEQ, the GEQ (A) and GEQ (B) within the
same rack will be linked.
• GEQ x
➞
y button (“x” and “y” are the rack number, or the rack number and
alphabetical character A or B)
The parameters of “x” will be copied to “y,” and then linked.
• GEQ y
➞
x button
The parameters of “y” will be copied to “x,” and then linked.
• RESET BOTH button
The parameters of both will be initialized, and then linked.
• CANCEL button
Cancels the link and closes the window.
NOTE
The RACK LINK button is shown only if linking is possible. When you link
GEQ units, a symbol will appear in the GEQ field to indicate the linked
status.
5
FLAT button
Returns all bands of the currently-selected GEQ to 0 dB.
6
GEQ ON/OFF button
Switches the currently-selected GEQ on or off.
For GEQ EDIT window (31BandGEQ, Flex15GEQ)
1
RTA button
Turn this button on to overlay a frequency response graph on the EQ.
2
HOLD button
Press this button to hold the peak of the graph that displays RTA.
2