Monitor and Cue functions
Reference Manual
104
4
Other CUE group
These cue signals are operated via buttons displayed on the
touch screen. This group is enabled if you turn on the CUE
button in the EFFECT window or the PREMIUM window, or
if you turn on the KEY IN CUE button in the DYNAMICS 1
window. This group will automatically be disabled when
you exit the corresponding window.
NOTE
You cannot turn on cue monitoring between different groups simultaneously. Normally, the group
to which the most recently-pressed [CUE] key (or on-screen CUE/KEY IN CUE button) belongs
will take priority, and the [CUE] keys for the previously-selected group will be defeated.
However, if you have switched the cue signal group in a specific order when the CUE MODE
setting is MIX CUE, the state of the [CUE] keys for the previously-selected group will be restored
when the current cue signal is defeated.
The right illustration shows the priority
order of the [CUE] keys. After you
have switched groups from lower to
upper levels, if you then defeat cue for
the upper group, the previous [CUE]
key status of the group immediately
below will be restored.
For example, if you switch groups in
the order of OUTPUT CUE group
DCA CUE group
INPUT CUE group
Other CUE group, you can then
successively defeat the [CUE] keys
(CUE/KEY IN CUE buttons) to
successively restore the [CUE] key
status of the previously-selected group.
Operating the Cue function
This section explains how to use the [CUE] key for a channel or DCA group to monitor cue
signals.
NOTE
Be aware that if you turn CUE INTERRUPTION off in the MONITOR popup window, the cue
signal will not be sent to the connected monitor speakers. However, the front panel PHONES jack
will always output the cue signal regardless of the Monitor on/off setting. See “
for details about the Monitor function.
On-screen CUE button
Other CUE group
INPUT CUE group
DCA CUE group
OUTPUT CUE group
STEP
1.
In the Function Access Area, press the MONITOR button.
2.
Press the CUE display button or the INPUT/DCA/OUTPUT CUE field in the MONITOR
screen.
3.
Use the CUE MODE button to select either the mode in which channels are mixed
for auditioning, or the mode in which only the last-selected channel is auditioned.
4.
Use the buttons and knobs of the INPUT CUE/DCA CUE/OUTPUT CUE field to specify
the output position and output level for each CUE group.
5.
Press one of the CUE OUT PATCH buttons (L/R) in the meter field to specify a port
as the output destination for cue signals L and R (multiple selections are allowed).
6.
To enable cue out for the port you specified in step 5, press the CUE OUTPUT button
to turn it on.
7.
Press the [CUE] key of the channel or DCA group to be monitored to turn it on.
8.
Adjust the cue signal level by using the [TOUCH AND TURN] knob to operate the
CUE LEVEL knobs in the CUE field.
9.
To defeat cue, press the currently-on [CUE] key once again. To clear all cue
selections, press the CLEAR CUE button in the Meter field.
MONITOR screen