Parameter Lock/Console Lock
33
Parameter Lock/Console Lock
In V1.6, the user can specify a password, and disable changes in specified parameters (Parameter Lock) or
prohibit console operations (Console Lock) until the correct password is input. This function is a convenient
way to prevent an unauthorized third party from tampering with the console while the engineer is resting.
There are two types of password; a “
system password
” that is common to the entire system, and a “
console
password
” that can be set for the individual console. These two may be set individually. Specifying the system
password allows you to use the Parameter Lock and Console Lock functions. Specifying the console password
allows you to use only the Console Lock function.
SECURITY screen
A SECURITY screen has been added to the UTILITY function, allowing you to input passwords and enable or defeat
Parameter Lock or Console Lock.
1
SYSTEM PASSWORD
This specifies the password for the entire system.
When using DUAL CONSOLE mode, the system
password is common to both consoles.
2
PARAMETER LOCK
When you turn this button on, the parameters
selected in the LOCK PARAMETER SELECT area
(
4
) will be locked.
If not even one parameter has been selected, this
button will be grayed-out, and cannot be turned
on.
3
CONSOLE LOCK
This button locks the console. You must input the
System Password in order to use this button to
enable/defeat Console Lock.
1
2
3