background image

PM1D Manager V2 for Windows Owner’s Manual

20

Special considerations

This section notes various things you should be aware of concerning the parameters and operations in each 
screen.

PREFERENCE switch

SELECTED INPUT CHANNEL / SELECTED 
OUTPUT CHANNEL

These settings are not linked with the console in the 
system, and can be set independently.

Hint

You can switch the channel directly by left-clicking or right-
clicking SELECTED INPUT CHANNEL / SELECTED 
OUTPUT CHANNEL field located in the lower part of the 
screen.

MODULE FLIP / FADER FLIP

These functions are specific to the console, and do 
not exist in PM1D Manager.

PREVIEW mode on/off (MEMORY screen)

This is not linked with the console in the system, and 
can be set independently.

If you exit PM1D Manager with Preview mode turned 
on, the content (Preview mode content) that was dis-
played when you last exited) will be recovered. However 
at this time, the PREVIEW button will be turned off. In 
the same way if you go offline with Preview mode 
turned on, the contents that had been Preview-dis-
played when online will be handled as Preview mode = 
off.

Fade time operation

Due to functional limitations, realtime control and 
monitoring of the fade time is not possible on PM1D 
Manager. Thus, the manual fade function cannot be 
used.

If you recall a scene for which a fade time setting has 
been specified, the faders/pan in PM1D Manager will 
immediately indicate the value that is to be reached 
after fading, and will stop there. However, if you 
operate a fader while the fade time is being executed, 
the fade for that channel will be cancelled, and the 
fader will remain at the position to which you moved 
it.

If the PC and engine alone are online, Fader Start 
control is performed from PM1D Manager. Thus, 
even if the scene has a fader time setting, Fader Start 
will function immediately after scene recall occurs.

MIDI program changes / control changes

The MIDI ports of the PC cannot be used as MIDI 
inputs/outputs for the PM1D Manager software.

TC events

The setting can always be made, but since operation 
in response to incoming time code is performed by 
the console itself, the following restrictions apply.

(*) It will not be possible to operate the EVENT RECALL-

ING button or TIME CODE IN button in the TC 
EVENT screen (MIDI/GPI/TC function).

It is not possible to output time code directly from the 
PC. Nor can the CAPTURE button operated from the 
PC.

Meters

The function of the meters will change as follows, 
depending on the online/offline status of PM1D 
Manager, and on the presence or absence of a con-
sole.

(*) Due to functional limitations, some meter data can be 

displayed only for a single selected channel within the 
system. In such cases, the channel selected on the con-
sole will be given priority.
In order to avoid inconsistencies due to the fact that 
the selected channel is not linked between the PC and 
console, this type of meter will not be displayed on the 
PC.
Also, the 

 meter will not be displayed on the PC.

CONFIRMATION
ON/OFF

These settings are not linked 
with the console in the system, 
and therefore must be set indi-
vidually.

WARNING MESSAGES 
ON/OFF

GATE/COMP GR 
METER ON/OFF LINK

INTERNAL 
CALENDAR/CLOCK

Since this indicates the date of 
the PC, it is not linked with the 
console. Make this setting in 
the Windows [Control Panel]-
[Date and time].

Others

These functions are specific to 
the console, and do not exist in 
PM1D Manager.
The SELECTED CH field in the 
AUTO DISPLAY area is not 
shown in PM1D Manager, but 
is always enabled.

Offline

Fixed at Preview mode = off

Online

Preview mode can be turned 
on/off

Offline

Function is valid (*)

Online

Console exists in 
the system

Function is valid

Console does not 
exist in the system

Function is invalid (*)

Offline

No meters will be dis-
played.

Online

Console exists in 
the system

Some meters will not 
be displayed. (*)

Console does not 
exist in the system

All meters will be dis-
played.

Содержание PM1D Manager V2

Страница 1: ...d Trademarks Windows is a registered trademark of Microsoft Corporation in the United States and other countries Pentium II is a registered trademark of Intel Corporation Compact Flash is a trademark...

Страница 2: ...display common to all screens 7 Lower part of the display common to all screens 7 Lower part of the function menu 8 Option popup window 8 REMOTE CONTROL SETUP popup window 9 Communication between PM1...

Страница 3: ...rols of the console and the knobs buttons of the software The names of controls on the console switches encoders are enclosed in square brackets in order to distinguish them from the knobs and buttons...

Страница 4: ...em you may be asked to restart the system during the installation process If so installation will continue automatically after you restart 3 As directed by the instructions on the screen click the Nex...

Страница 5: ...ther of the following methods to start up PM1D Manager 1 From the Windows Start menu select Start Programs YAMAHA PM1D System PM1D Manager 2 Double click the PM1D Manager icon that was cre ated during...

Страница 6: ...k either the Initialize All Memories button or the Initialize Current Memories button If you click the Initialize All Memories button The current settings of the PM1D Manager as well as the scene memo...

Страница 7: ...ication Setup Lower part of the display common to all screens 1 RECALL button MUTE button Select the function of the DIRECT RECALL MUTE MASTER 1 12 buttons 2 from the following two choices DIRECT RECA...

Страница 8: ...func tion menu screen or choose Manager from the Option menu of the menu bar 1 Communication Setup Communication Port From the pulldown menu select the port that will be used for communication Only C...

Страница 9: ...r has been established 4 CH ASSIGN Here you can assign the correspondence between input channels of the remote controller and input channels of the PM1D in units of two channels If you don t want to m...

Страница 10: ...ed and terminated System connection examples Example 1 Standard mode connect the PC to the console Console 1 Engine 1 Example 2 Standard mode connect the PC to the engine Example 3 Mirror mode connect...

Страница 11: ...off the console engine or connect disconnect cables If you perform these actions before exiting communication may become impossible until you restart your PC USB connection is not guaranteed to be fa...

Страница 12: ...nd slave are handled separately so this is considered as two systems 6 In the Function menu screen click the ONLINE OFFLINE button The following popup window will appear In this popup window you can s...

Страница 13: ...to the engine system example 4 on p 10 When a console is connected to a system that consisted of only an engine and a PC system example 5 on p 10 When the cable connection is accidentally broken or if...

Страница 14: ...1 3 Start up PM1D Manager and open the Option popup window either by clicking the OPTION but ton in the lower left of the function menu screen or by choosing Manager Option from the Option menu in the...

Страница 15: ...G Hi Mid Q Hi Mid Q Hi Mid F Hi Mid F Hi Mid G Hi Mid G Hi LPF Hi Q When LPF Hi H SHELF When H SHELF Hi Q When other than H SHELF or LPF Hi F Hi Mid F Hi G Hi Mid G Hi LPF Ignored LPF On On On Input...

Страница 16: ...G Ignored HPF On SubLow On Ignored Low Q Low Mid Q Low F Low Mid F Low G Low Mid G Low On Ignored Low Mid Q Hi Mid Q Low Mid F Hi Mid F Low Mid G Hi Mid G Low Mid On Ignored Mid Q Mid F Mid G Mid On I...

Страница 17: ...id G Low Mid On Ignored Mid Q Ignored Mid F Ignored Mid G Ignored Mid On Ignored Hi Mid Q Hi Mid F Hi Mid G Hi Mid On Ignored Hi LPF Hi Q When LPF Hi H SHELF When H SHELF Hi Q When other than H SHELF...

Страница 18: ...Hi LPF Ignored LPF On Hi On Ignored On On Stereo Comp Ignored Stereo Comp LocComp On On Ignored Link Type Type Attack Attack Release Release Ratio Ratio Gain Gain Knee Knee Threshold Threshold Input...

Страница 19: ...n 16 the data is fixed as space on the remote controller Mute Master 9 12 Output Mute Master Surround Mode Surround Mode Input CH Name Short Input CH Name Short column1 4 Input CH Name Long Input CH N...

Страница 20: ...recall occurs MIDI program changes control changes The MIDI ports of the PC cannot be used as MIDI inputs outputs for the PM1D Manager software TC events The setting can always be made but since oper...

Страница 21: ...e in the system and can therefore be operated independently LOAD SAVE screen The number of characters that can be used in a file name is eight characters plus the filename extension PM1 If this number...

Страница 22: ...n the Copy files from sec tion of the subsequent dialog box enter D USBdrv2k_ replacing D with the drive letter of your CD ROM drive and then click OK The driver is installed and the message Completin...

Страница 23: ...SB Driver fails the CS1D DSP1D may be registered as an unknown device and you may not be able to rein stall the driver until the unknown device is deleted In this case open the System control panel cl...

Страница 24: ...U R G Pro Audio Digital Musical Instrument Division Yamaha Corporation 2002 Yamaha Corporation WF52700 806IPAPx x 0xA1 Printed in Japan...

Отзывы: