Remote Control functionality

If you connect PM1D Manager to a Yamaha digital mixer 
(DM2000 V2, 02R96 V2, and DM1000 V2) via USB, you 
will be able to use the digital mixer (subsequently 
referred to as the “remote controller”) to remotely con-
trol the PM1D system.

• The digital mixers that can be used for remote control are 

only the DM2000 V2, 02R96 V2, and DM1000 V2, and 
each must be running system software V2. Remote con-
trol from other mixers is not possible.

• If you use a remote control device, the scene data and 

setup data stored in the digital mixer (DM2000 V2, 
02R96 V2, DM1000 V2) will be rewritten. Please back up 
all of your digital mixer’s data to a computer or other 
external media before you use the remote control func-
tions. For details on how to back up, refer to the manual 
of your digital mixer.

• The PM1D system’s parameters that can be remotely con-

trolled are the HA GAIN or digital gain, ATT, EQ, GATE, 
COMP, MIX SEND, FADER, ON, SURROUND, CUE/
SOLO ON, DCA, and scene parameters. For details, refer 
to the remote control parameter list (

p.15).

• Parameters that do not match between the remote con-

troller and the PM1D will be controlled to the value that 
is closest to the parameter value that was operated. This 
means that the actual value may differ from the displayed 
value.

Setup procedure

1. Make a USB or serial connection between the con-

sole/engine and the PC, and a USB connection 
between the remote controller and the PC.

2. In the SETUP screen of the remote controller, go to 

the MIDI/HOST page and set the Studio Manager 
PORT to “USB” and the ID to “1.”

3. Start up PM1D Manager, and open the Option 

popup window either by clicking the OPTION but-
ton in the lower left of the function menu screen or 
by choosing [Manager Option] from the [Option] 
menu in the menu bar.

4. In the Option window, make the port settings 

shown below, and click [OK].

Communication Port: 

Select the port that you will 

use to communicate with the console/engine.

Remote Control Setup: 

Select the USB input port 

(IN PORT) and output port (OUT PORT) used to 
communicate with the remote controller. If the con-
nection with the console/engine is also a USB con-
nection, be careful that you don’t select the console/
engine port by mistake.

5. From the menu bar, choose [Option] menu 

 

[Remote Control Setup] to open the REMOTE 
CONTROL SETUP popup window.

6. In the REMOTE CONTROL SETUP window, select 

the model name of the remote controller you’re 
using in the REMOTE MACHINE field.

7. In the REMOTE CONTROL SETUP window, make 

channel assignments for the remote controller and 
for the PM1D (

p.9).

8. In the function menu screen, click the REMOTE 

ONLINE/OFFLINE button (or the RE-SYNCHRO-
NIZE button in the REMOTE CONTROL SETUP 
windows) to enable Online status for communica-
tion with the remote controller.

9. In the function menu screen, click the ONLINE/

OFFLINE button to enable Online status for com-
munication with the console/engine.

This completes preparations for remote control.

10. In this state, operating the parameters on the 

remote controller will also control the correspond-
ing parameters on the PM1D.

For details on the parameters supported for remote 
control, refer to the remote control parameter list 
(

p.15).

Yamaha digital mixer 

(DM2000 V2, 02R96 V2, 

DM1000 V2)

PM1D Manager

Console CS1D

Engine 

DSP1D/DSP1D-EX

USB

USB/RS-232C

PM1D V2 system

Click

REMOTE ONLINE/
OFFLINE button

ONLINE/
OFFLINE button

Содержание PM1D Manager V2

Страница 1: ...d Trademarks Windows is a registered trademark of Microsoft Corporation in the United States and other countries Pentium II is a registered trademark of Intel Corporation Compact Flash is a trademark...

Страница 2: ...display common to all screens 7 Lower part of the display common to all screens 7 Lower part of the function menu 8 Option popup window 8 REMOTE CONTROL SETUP popup window 9 Communication between PM1...

Страница 3: ...rols of the console and the knobs buttons of the software The names of controls on the console switches encoders are enclosed in square brackets in order to distinguish them from the knobs and buttons...

Страница 4: ...em you may be asked to restart the system during the installation process If so installation will continue automatically after you restart 3 As directed by the instructions on the screen click the Nex...

Страница 5: ...ther of the following methods to start up PM1D Manager 1 From the Windows Start menu select Start Programs YAMAHA PM1D System PM1D Manager 2 Double click the PM1D Manager icon that was cre ated during...

Страница 6: ...k either the Initialize All Memories button or the Initialize Current Memories button If you click the Initialize All Memories button The current settings of the PM1D Manager as well as the scene memo...

Страница 7: ...ication Setup Lower part of the display common to all screens 1 RECALL button MUTE button Select the function of the DIRECT RECALL MUTE MASTER 1 12 buttons 2 from the following two choices DIRECT RECA...

Страница 8: ...func tion menu screen or choose Manager from the Option menu of the menu bar 1 Communication Setup Communication Port From the pulldown menu select the port that will be used for communication Only C...

Страница 9: ...r has been established 4 CH ASSIGN Here you can assign the correspondence between input channels of the remote controller and input channels of the PM1D in units of two channels If you don t want to m...

Страница 10: ...ed and terminated System connection examples Example 1 Standard mode connect the PC to the console Console 1 Engine 1 Example 2 Standard mode connect the PC to the engine Example 3 Mirror mode connect...

Страница 11: ...off the console engine or connect disconnect cables If you perform these actions before exiting communication may become impossible until you restart your PC USB connection is not guaranteed to be fa...

Страница 12: ...nd slave are handled separately so this is considered as two systems 6 In the Function menu screen click the ONLINE OFFLINE button The following popup window will appear In this popup window you can s...

Страница 13: ...to the engine system example 4 on p 10 When a console is connected to a system that consisted of only an engine and a PC system example 5 on p 10 When the cable connection is accidentally broken or if...

Страница 14: ...1 3 Start up PM1D Manager and open the Option popup window either by clicking the OPTION but ton in the lower left of the function menu screen or by choosing Manager Option from the Option menu in the...

Страница 15: ...G Hi Mid Q Hi Mid Q Hi Mid F Hi Mid F Hi Mid G Hi Mid G Hi LPF Hi Q When LPF Hi H SHELF When H SHELF Hi Q When other than H SHELF or LPF Hi F Hi Mid F Hi G Hi Mid G Hi LPF Ignored LPF On On On Input...

Страница 16: ...G Ignored HPF On SubLow On Ignored Low Q Low Mid Q Low F Low Mid F Low G Low Mid G Low On Ignored Low Mid Q Hi Mid Q Low Mid F Hi Mid F Low Mid G Hi Mid G Low Mid On Ignored Mid Q Mid F Mid G Mid On I...

Страница 17: ...id G Low Mid On Ignored Mid Q Ignored Mid F Ignored Mid G Ignored Mid On Ignored Hi Mid Q Hi Mid F Hi Mid G Hi Mid On Ignored Hi LPF Hi Q When LPF Hi H SHELF When H SHELF Hi Q When other than H SHELF...

Страница 18: ...Hi LPF Ignored LPF On Hi On Ignored On On Stereo Comp Ignored Stereo Comp LocComp On On Ignored Link Type Type Attack Attack Release Release Ratio Ratio Gain Gain Knee Knee Threshold Threshold Input...

Страница 19: ...n 16 the data is fixed as space on the remote controller Mute Master 9 12 Output Mute Master Surround Mode Surround Mode Input CH Name Short Input CH Name Short column1 4 Input CH Name Long Input CH N...

Страница 20: ...recall occurs MIDI program changes control changes The MIDI ports of the PC cannot be used as MIDI inputs outputs for the PM1D Manager software TC events The setting can always be made but since oper...

Страница 21: ...e in the system and can therefore be operated independently LOAD SAVE screen The number of characters that can be used in a file name is eight characters plus the filename extension PM1 If this number...

Страница 22: ...n the Copy files from sec tion of the subsequent dialog box enter D USBdrv2k_ replacing D with the drive letter of your CD ROM drive and then click OK The driver is installed and the message Completin...

Страница 23: ...SB Driver fails the CS1D DSP1D may be registered as an unknown device and you may not be able to rein stall the driver until the unknown device is deleted In this case open the System control panel cl...

Страница 24: ...U R G Pro Audio Digital Musical Instrument Division Yamaha Corporation 2002 Yamaha Corporation WF52700 806IPAPx x 0xA1 Printed in Japan...

Отзывы: