5-3
5-2
5
Troubleshooting
Magnetic pole detection error
3.
Magnetic pole detection error
Magnetic pole detection error
Motor wire is disconnected.
External force or friction is applied
to slider when power is turned on.
Turn power off and check slider
movement by moving it by hand.
Check wiring by referring to
robot manual.
Robot mechanical movement is
heavy at point where power is
turned on.
Repair the robot. *
Correct wiring or replace
defective connector pins.
Connector wiring is incorrect.
Securely make connections.
Remove external force and
friction and restart the robot.
Consult us.
YES
NO
NO
NO
NO
YES
YES
YES
Requires repair or parts replacement.
Contact us.
* Try to turn on power in another
place to check whether the robot
operates normally.