13.4. Message list
Messages appearing in the display of the PC-D/DI series and the appropriate actions are listed below.
■
Alert Message
■
Log Message
Number
Alert
Message
Log
Message
SEVERITY
Content
Action
01
-
POWER TURNED
ON
INFORMATION
- The power turned
on, or - Software
reboot was
executed
-
02
-
POWER TURNED
OFF
INFORMATION
- The power turned
off, or - Software
reboot was
executed
-
03
-
STANDBY MODE
TO NORMAL
INFORMATION
The unit
transitioned from
standby mode to
normal operating
mode.
-
04
-
NORMAL MODE
TO STANDBY
INFORMATION
The unit
transitioned from
normal operating
mode to standby
mode.
-
05
Amplifier Output
Muting
AMP OUTPUT
MUTING
ERROR
The protection
function operated
to mute the amp
output.
Take action to
clear the
protection function
that was the
cause.
The cause is
indicated by
another alert that
is shown at the
same time.
12
Mains Voltage
Over 276[V]
MAINS OVER 276V ERROR
(at startup) The
amp cannot start
up because the
power supply
voltage exceeded
the allowable
operating voltage.
Connect a stable
power supply that
is within the power
supply
requirements.
The amp stopped
because the power
supply voltage
exceeded the
allowable
operating voltage.