Utility
MOTIF-RACK XS Owner’s Manual
100
Basic Structure
Ref
erence
V
oice
Multi
Utility
The Contr
ols &
Connector
s
Setting Up
Listening to
the Sound
Connections
Using a Computer
Quic
k Guide
Appendix
Local Control
This determines whether or not the tone generator of the instrument responds to turning Knobs 1 – 5.
If you set “Local Control” to “off,” the Knobs are internally disconnected from the tone generator.
Even if this is set to “off,” the data will be transmitted via MIDI. Also, the internal tone generator will
respond to messages received via MIDI.
Settings:
off (disconnect), on (connect)
Device No.
(Device Number)
Determines the MIDI Device Number. This number must match the Device Number of the DAW
software or the external MIDI device when transmitting/receiving Bulk Dump data, parameter
changes or other System Exclusive messages.
Settings:
1 – 16, all, off
all........................... When this is selected, System Exclusive messages for all MIDI device numbers are received. When
System Exclusive messages such as Bulk Dump are transmitted from the MOTIF-RACK XS with this
setting, the MOTIF-RACK XS is recognized as Device Number 1.
off .......................... When this is selected, System Exclusive messages such as Bulk Dump and parameter change cannot
be transmitted or received. When you try executing transmission or reception of System Exclusive
messages, an error message appears.
Bank Select Sw
(Bank Select Switch)
Determines whether or not Bank Select messages are transmitted or received. When this is set to
“on,” this tone generator responds to incoming Bank Select messages, and it also transmits
appropriate Bank Select messages (when using the panel). When this is set to “off,” Bank Select
messages cannot be transmitted/received.
Settings:
off, on
Prg Change Sw
(Program Change Switch)
Determines whether or not Program Change messages are transmitted or received. When this is set
to “on,” this tone generator responds to incoming Program Change messages, and it also transmits
appropriate Program Change messages (when using the panel). When this is set to “off,” Program
Change messages cannot be transmitted/ received.
Settings:
off, on
Receive Bulk
Determines whether or not Bulk Dump data from the DAW software or the external MIDI devices can
be received.
Settings:
protect (not received), on (received)
Controller Reset
Determines the status of the controllers (Modulation Wheel, Aftertouch, Foot Controller, Breath
Controller, Knobs, etc.) when switching between voices. When this is set to “hold,” the controllers are
kept at the current setting. When this is set to “reset,” the controllers are reset to the default states
(below).
Settings:
hold, reset
If you select “reset,” the controllers will be reset to the following states/positions:
Pitch Bend: Center; Modulation Wheel: Minimum; Aftertouch: Minimum; Foot Controller: Maximum; Foot switch: Off; Ribbon
Controller: Center; Breath Controller: Maximum; Assignable Function: Off; Expression: Maximum; Sustain: Off
Bulk Interval
Determines the interval time of the Bulk Dump transmission when the Bulk Dump function is used or
the Bulk Dump Request is received. The Bulk Dump function lets you save the current Voice/Multi
data in the Edit buffer (DRAM) and transmit as Bulk data (System Exclusive message) to the DAW
software on a computer or an external MIDI instrument.
Settings:
0, 10ms, 20ms, 30ms
MIDI Soft Thru
(MIDI Soft Thru Switch)
Determines whether received MIDI data is re-transmitted (as well as via which output) when the
“MIDI In/Out” is set to “MIDI.” If you have not connected a USB cable to the MOTIF-RACK XS, even
if “MIDI In/Out” is set to “USB,” this setting will be available since the MIDI terminal will be
automatically used for transmitting/receiving MIDI data.
Settings:
off, on
n
If you want to re-transmit received MIDI Clock messages (F8) via the MIDI OUT (Soft Thru) jack, set this parameter
to “on,” and also set the Clock Out parameter (above) to “off” so that transmission of MIDI Clock messages of the
MOTIF-RACK XS is disabled.
Quick Setup
When the cursor is located here, pressing the [ENTER] button or the Encoder knob calls up the
Quick Setup dialog (page 101). MOTIF-RACK XS has three combinations of the following parameter
settings as appropriate for basic operations: Local Control, MIDI Sync, Clock Out, Arp MIDI Out Sw.
These combinations can be selected and executed at the Quick Setup dialog, letting you instantly
change all settings depending on your particular application or intended use. The three
combinations can be changed by setting the following parameters in this Utility MIDI window.
QS 1 – 3 Local Control
(Quick Setup 1 – 3 Local Control)
QS 1 – 3 MIDI Sync
(Quick Setup 1 – 3 MIDI Sync)
QS 1 – 3 Clock Out
(Quick Setup 1 – 3 Clock Out)
QS 1 – 3 Arp MIDI Out Sw
(Quick Setup 1 – 3 Arpeggio MIDI
Out Switch)
Changes each parameter settings of the Quick Setup 1 – 3.
Settings:
Local Control ........ off, on
MIDI Sync .............. .internal, external, auto
Clock Out ............. .off, on
Arp MIDI Out Sw ... all off, all on
Содержание Motif-Rack XS