4. Screens
MMP1 Operation Manual
15
4-1-3. Sub screen
This is the Sub screen used for monitor control.
NOTE
You can use this screen when logged in as an “Administrator” or “Advanced User.”
4-1-3a. Meters
Here you can display Monitor Matrix Out meters. These
channels include Monitor outputs (up to 32 ch), Downmix
L/R, and Headphone L/R.
NOTE
The meters shown here are the same as those on the Main
screen.
Values less than -20 dB are displayed in green
, values
less than 0 dB in yellow
, and values equal to or above 0
in red
. Peak hold circuits are not displayed.
NOTE
• The breakdown of Monitor outputs is based on the format
selected under “Monitor Matrix Out” in the “Monitor Matrix” tab
of the “Scene” tab on the Settings screen.
• The signal position displayed on the meters can be selected in
the “System” tab of the “Scene” tab on the Settings screen.
Meters
Displays Monitor Matrix Out meters
Monitor section
For adjusting input source and Send levels
Oscillator section
For selecting signals
to output from the
oscillator, and
adjusting their output
levels
Snapshot section
For storing and recalling
Snapshots
Talkback section
For selecting Talkback
interrupt destinations
and adjusting Talkback
output levels
Click these buttons to set all Main Monitor
outputs to SOLO or MUTE.
/
Click these buttons to turn each Main Monitor
SOLO or MUTE setting on (lights up) or off.
Click these buttons to turn the oscillator on (lit)
or off. You can select the oscillator type used in
the “Oscillator” section on the Sub screen.
represents sine waves and
represents pink
noise.
This is displayed when using Talkback.